Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Enhanced Contingency Analysis—A Power System Operator Tool (CROSBI ID 292466)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bulat, Hrvoje ; Franković, Dubravko ; Vlahinić, Saša Enhanced Contingency Analysis—A Power System Operator Tool // Energies (Basel), 14 (2021), 4; 1-21. doi: 10.3390/en14040923

Podaci o odgovornosti

Bulat, Hrvoje ; Franković, Dubravko ; Vlahinić, Saša

engleski

Enhanced Contingency Analysis—A Power System Operator Tool

Contingency analysis (CA) is a well-known function in power system planning andoperation. In accordance with CA results, the system operator dispenses information regardingstatic security of the power system (overloads and/or voltage outside tolerable limits). However, classic CA with remedial action schemes cannot distinguish safe operating regimes from potentiallydangerous ones in terms of voltage (in)stability. In fact, voltage instability is considered as one of themajor threats leading to power system insecurity. Therefore, in this study an enhanced contingencyanalysis (ECA) is presented where the classical CA is extended with static voltage analysis based onthe modal analysis. The article presents a dedicated methodology for the proposed ECA tool, withspecial emphasis on the analysis of corrective measures provided by the system operator, intendedfor enhancing power system security (regulation transformer action, distributed generation andenergy storage). Also the influence of the load model was analyzed by simulation and the mainconclusions are presented. The study demonstrated the advantages that distributed generationresources and energy storage can provide in the context of voltage stability. Also, the simulationsacknowledged the importance of correct load modeling, since over or under estimation of a certainload-type component can result in too optimistic or too pessimistic power system operation limits.

contingency analysis ; voltage stability ; modal analysis ; distributed generation ; energy storage ; electric load model

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

14 (4)

2021.

1-21

objavljeno

1996-1073

10.3390/en14040923

Trošak objave rada u otvorenom pristupu

APC

Povezanost rada

Elektrotehnika

Poveznice
Indeksiranost