Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Sustainable management of water resources in supplementary irrigation management (CROSBI ID 291655)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Marković, Monika ; Krizmanić, Goran ; Brkić, Andrija ; Atilgan, Atilgan ; Japundžić Palenkić, Božica ; Petrović, Davor ; Barač, Željko Sustainable management of water resources in supplementary irrigation management // Applied sciences (Basel), 11 (2021), 6; 2451, 14. doi: 10.3390/app11062451

Podaci o odgovornosti

Marković, Monika ; Krizmanić, Goran ; Brkić, Andrija ; Atilgan, Atilgan ; Japundžić Palenkić, Božica ; Petrović, Davor ; Barač, Željko

engleski

Sustainable management of water resources in supplementary irrigation management

Watermark, Tensiometer and Time Domain Reflectometry (TDR) are commonly used soil water sensors in irrigation practice whose performance depends on soil type, depth and growing conditions. Here, the results of sensor performance evaluation in different soil depths as well as the field and laboratory testing in silty clay loamy soil are presented. Gravimetric soil moisture samples were taken from sensor installation depths (10, 20, 30 and 45 cm) and used as reference Soil Water Content (SWC). The measurements varied significantly (p < 0.05) across the monitoring depths. On average across the soil depths, there was a strong negative linear relationship between Watermark (r = -0.91) and TDR (r = 0.94), and a moderate negative (r = -0.75) linear relationship between SWC and Tensiometer. In general, Watermark and Tensiometer measured SWC with great accuracy in the range of readily available water, generated larger Mean Difference (MD) than TDR and overestimated SWC, while TDR underestimated SWC. Overall, laboratory testing reduced the root mean square error (RMSE, Watermark = 1.2, Tensiometer = 2.6, TDR = 1.9) and Mean Average Error (MAE, Watermark = 0.9, Tensiometer = 2.04. TDR = 1.04) for all tested sensors.

sensor performance ; field testing ; laboratory testing ; statistical analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

11 (6)

2021.

2451

14

objavljeno

2076-3417

10.3390/app11062451

Povezanost rada

Poljoprivreda (agronomija)

Poveznice
Indeksiranost