The impact of building zone elements on airtightness (CROSBI ID 699903)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Gumbarević, Sanjin ; Milovanović, Bojan ; Gaši, Mergim ; Bagarić, Marina The impact of building zone elements on airtightness // Proceedings of the 2nd International Conference CoMS 2020/21 - Volume 1 / Šajna, Aljoša ; Legat, Andraž ; Jordan, Sabina et al. (ur.). Ljubljana: Slovenian National Building and Civil Engineering Institute (ZAG), 2021. str. 106-114

Podaci o odgovornosti

Gumbarević, Sanjin ; Milovanović, Bojan ; Gaši, Mergim ; Bagarić, Marina

engleski

The impact of building zone elements on airtightness

To achieve the goals set by the European Union (EU) in terms of energy savings and decrease of the greenhouse gas emissions, the member states of the EU obliged that they would increase the number of the Nearly Zero Energy Buildings (NZEB). That increase has to be accomplished not only by building new NZEBs but also by deep energy renovations of old ones. One of the criteria to fulfil NZEB demands is to ensure the airtightness of the building, which is usually tested by an air pressurisation test. As there will be a great number of buildings which must undergo the testing in the near future, it is important to find a way to speed up the testing for the multizone buildings. This paper presents research based on the results of building zone airtightness estimations based on a fan pressurisation test by the so-called Blower Door system. It is a part of research whose goal is to develop a predictive model of the air-change-rate for a multizone building based on randomly tested zones. The paper describes a connection between the airtightness of tested building zones and elements which make up these zones. This research is crucial as a starting point for the development of the predictive model in order to define the parameters that affect these measurements. Statistical analysis was performed not only for the analysed results but also for an exploration of the connection between the zone elements and the zone’s airtightness as well. The paper presents a hypothesis based on the abovementioned research and proposes further research for the future development of the model.

Airtightness, Fan Pressuri sation Testing, Statistical Analysis, Nearly Zero -Energy Buildings, Blower Door

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

106-114.

2021.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the 2nd International Conference CoMS 2020/21 - Volume 1

Šajna, Aljoša ; Legat, Andraž ; Jordan, Sabina ; Horvat, Petra ; Kemperle, Ema ; Dolenec, Sabina ; Ljubešek, Metka ; Michelizza, Matej

Ljubljana: Slovenian National Building and Civil Engineering Institute (ZAG)

978-961-94071-8-9

Podaci o skupu

Construction Materials for a Sustainable Future (CoMS_2020/2021)

predavanje

20.04.2021-21.04.2021

Bled, Slovenija; online

Povezanost rada

Građevinarstvo, Temeljne tehničke znanosti