Power System Transient Stability Assessment Simulations Dataset - IEEE New England 39-bus test case (CROSBI ID 788519)

Druge vrste radova | ostalo

Sarajcev, Petar ; Kunac, Antonijo ; Petrovic, Goran ; Despalatovic, Marin Power System Transient Stability Assessment Simulations Dataset - IEEE New England 39-bus test case. 2021.

Podaci o odgovornosti

Sarajcev, Petar ; Kunac, Antonijo ; Petrovic, Goran ; Despalatovic, Marin

engleski

Power System Transient Stability Assessment Simulations Dataset - IEEE New England 39-bus test case

This dataset contains phasor measurements (PMU-type) signals from the IEEE New England 39-bus power system test case network, which are generated from a large corpus of systematic MATLAB®/Simulink electro-mechanical transients simulations. It was prepared to serve as a convenient and open database for experimenting with different types of machine learning (including deep learning) techniques for transient stability assessment (TSA) of electrical power systems. A dataset contains time-domain signals from 9360 simulations. Different load and generation levels of the New England 39-bus benchmark power system are systematically covered, as well as all three major types of short-circuit events (three-phase, two-phase and single-phase faults) in all parts of the network. The consumed power of the network was set to 80%, 90%, 100%, 110% and 120% of the basic system load levels (for different system load levels, both generation and loads are scaled by the same ratio). The short-circuits are located on the busbar or on the transmission line (TL). When they are located on a TL, it was assumed that they can occur at 20%, 40%, 60%, and 80% of the line length. Timing of the fault occurrences takes into the consideration a moment on the instantaneous sinusoidal reference voltage. The observation period of each simulation was set at 3 seconds and signals are sampled at 1/60 s resolution. Many different machine electrical and mechanical (rotor and stator quantities), as well as network (three-phase currents and voltages), time-domain signals are obtained from simulations with a PMU-type resolution.

power system ; transient stability ; machine learning ; deep learning ; MATLAB ; dataset