Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Smartphone Based Range of Motion Measurement in Physiotherapy (CROSBI ID 698956)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Njirjak, Marko ; Otovic, Erik ; Budimir, Marko ; Vlahovic, Hrvoje ; Tomic, Mladen ; Marijančić, Verner Smartphone Based Range of Motion Measurement in Physiotherapy // Proceedings of the 43rd International Convention MIPRO 2020. 2020. str. 197-202 doi: 10.23919/MIPRO48935.2020.9245214

Podaci o odgovornosti

Njirjak, Marko ; Otovic, Erik ; Budimir, Marko ; Vlahovic, Hrvoje ; Tomic, Mladen ; Marijančić, Verner

engleski

Smartphone Based Range of Motion Measurement in Physiotherapy

Range of motion measurement is often performed in physiotherapy. It is important for both initial patient's joint health status evaluation, and later on for tracking progress of a rehabilitation therapy. Standard goniometers are often cumbersome to use and many therapists resort to approximative by eye angle assessment. In this paper, we investigate a modern smartphone application goniometer, based on an inertial measurement unit (IMU). We analyze IMU properties and their influence on angle measurement accuracy. The application is tested in a controlled environment and later on in real-life situations. The same set of measurements is performed by experienced physiotherapist using both the smartphone application and traditional goniometers. Shoulder abduction and elbow pronation and supination were examined. The results obtained clearly show that the smartphone application is comparable in accuracy to traditional ways of measurement. There was no statistically significant difference between the measurements made with traditional instruments and the mobile application. It was shown that for some ROM measurements it was efficient and easy to use and can be considered to be a viable and a better alternative to traditional goniometers.

Tracking , Goniometers , User experience , Time measurement , Read only memory , Standards , Testing

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

197-202.

2020.

objavljeno

10.23919/MIPRO48935.2020.9245214

Podaci o matičnoj publikaciji

Podaci o skupu

MIPRO 2020

predavanje

28.09.2020-02.10.2020

Opatija, Hrvatska

Povezanost rada