Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Building Performance Evaluation of a New Hospital Building in the UK: Balancing Indoor Environmental Quality and Energy Performance (CROSBI ID 288954)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Jain, Nishesh ; Burman, Esfand ; Stamp, Samuel ; Shrubsole, Clive ; Bunn, Roderic ; Oberman, Tin ; Barrett, Edward ; Aletta, Francesco ; Kang, Jian ; Raynham, Peter et al. Building Performance Evaluation of a New Hospital Building in the UK: Balancing Indoor Environmental Quality and Energy Performance // Atmosphere, 12 (2021), 1; 115, 23. doi: 10.3390/atmos12010115

Podaci o odgovornosti

Jain, Nishesh ; Burman, Esfand ; Stamp, Samuel ; Shrubsole, Clive ; Bunn, Roderic ; Oberman, Tin ; Barrett, Edward ; Aletta, Francesco ; Kang, Jian ; Raynham, Peter ; Mumovic, Dejan ; Davies, Mike

engleski

Building Performance Evaluation of a New Hospital Building in the UK: Balancing Indoor Environmental Quality and Energy Performance

Hospitals are controlled yet complex ecosystems which provide a therapeutic environment that promotes healing, wellbeing and work efficiency for patients and staff. As these buildings accommodate the sick and vulnerable, occupant wellbeing and good indoor environmental quality (IEQ) that deals with indoor air quality (IAQ), thermal comfort, lighting and acoustics are important objectives. As the specialist nature of hospital function demands highly controlled indoor environments, this makes them energy intensive buildings due to the complex and varying specifications for their functions and operations. This paper reports on a holistic building performance evaluation covering aspects of indoor air quality, thermal comfort, lighting, acoustics, and energy use. It assesses the performance issues and inter-relationships between IEQ and energy in a new building on a hospital campus in the city of Bristol, United Kingdom. The empirical evidence collated from this case study and the feedback received from the hospital staff help identify the endemic issues and constraints related to hospital buildings, such as the need for robust ventilation strategies in hospitals in urban areas that mitigate the effect of indoor and outdoor air pollution and ensuring the use of planned new low-carbon technologies. Whilst the existing guidelines for building design provide useful instructions for the protection of hospital buildings against ingress of particulate matter from outdoors, more advanced filtration strategies may be required to enact chemical reactions required to control the concentration levels of pollutants such as nitrogen dioxide and benzene. Further lessons for improved performance in operation and maintenance of hospitals are highlighted. These include ensuring that the increasingly available metering and monitoring data in new buildings, through building management systems, is used for efficient and optimal building operations for better IEQ and energy management. Overall, the study highlights the need for an integrated and holistic approach to building performance to ensure that healthy environments are provided while energy efficiency targets are met.

building performance evaluation ; indoor environmental quality (IEQ) ; indoor air quality (IAQ) ; energy performance ; hospitals

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

12 (1)

2021.

115

23

objavljeno

2073-4433

10.3390/atmos12010115

Povezanost rada

Arhitektura i urbanizam, Građevinarstvo, Interdisciplinarne tehničke znanosti, Javno zdravstvo i zdravstvena zaštita

Poveznice
Indeksiranost