Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Reliability of the Measurement Method in Determining the Mass Concentration of Hardwood Dust (CROSBI ID 288714)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Čavlović, Anka Ozana ; Bešlić, Ivan ; Zgorelec, Željka ; Ožegović Josip Reliability of the Measurement Method in Determining the Mass Concentration of Hardwood Dust // BioResources, 16 (2021), 1; 643-654. doi: 10.15376/biores.16.1.643-654

Podaci o odgovornosti

Čavlović, Anka Ozana ; Bešlić, Ivan ; Zgorelec, Željka ; Ožegović Josip

engleski

Reliability of the Measurement Method in Determining the Mass Concentration of Hardwood Dust

The reliability of the measurement method in determining the mass concentration of wood dust relates to the sampling time for the detection of wood particles in the ambient air of woodworking places. The aim of this study was to calculate the mass Limit of detection (LOD) and Limit of quantification (LOQ) and the minimal sampling time (tLOD and tLOQ) for determination and quantification of samples, based on the hardwood dust mass concentration at various woodworking places in the sawmills, floor production factories, and carpentries. Determination of the mass concentration of respirable, inhalable, and total hardwood dust from ambient air was performed using personal sampling pumps and three types of filter holders: respirable dust cyclone, Institute of Occupational Medicine IOM inhalable dust sampler, and total dust open-faced filter holder. The average limit of detection amounts to 0.052, 0.083, and 0.167 mg for respirable, inhalable, and total hardwood dust, respectively. The minimal detection sampling time for collecting all observed types of dust fractions ranged between 1.12 h and 1.72 h. The minimal quantification time for all collected hardwood dust samples ranged from 3.75 h to 5.51 h. Pearson's correlation test showed that the reliability of the measurements was affected more by the dustiness of the workspace than the real sampling time.

Wood dust ; Inhalable fraction ; Minimal sampling time ; Limit of detection ; Limit of quantification

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

16 (1)

2021.

643-654

objavljeno

1930-2126

10.15376/biores.16.1.643-654

Trošak objave rada u otvorenom pristupu

Povezanost rada

Drvna tehnologija, Javno zdravstvo i zdravstvena zaštita, Šumarstvo

Poveznice
Indeksiranost