Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Procjena parametara boje gornjih desnih središnjih sjekutića uporabom spektrofotometra i RAW fotografija s mobilnog uređaja u različitim uvjetima osvjetljenja (CROSBI ID 287388)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Soldo, Mirko ; Illeš, Davor ; Ćelić, Robert ; Knezović Zlatarić, Dubravka Assessment of Color Parameters on Maxillary Right Central Incisors Using Spectrophotometer and RAW Mobile Photos in Different Light Conditions / Procjena parametara boje gornjih desnih središnjih sjekutića uporabom spektrofotometra i RAW fotografija s mobilnog uređaja u različitim uvjetima osvjetljenja // Acta stomatologica Croatica, 54 (2020), 4; 353-362. doi: 10.15644/asc54/4/2

Podaci o odgovornosti

Soldo, Mirko ; Illeš, Davor ; Ćelić, Robert ; Knezović Zlatarić, Dubravka

hrvatski

Procjena parametara boje gornjih desnih središnjih sjekutića uporabom spektrofotometra i RAW fotografija s mobilnog uređaja u različitim uvjetima osvjetljenja

Abstract Objectives: The aim of the study was to compare three color parameters assessed on the maxillary right central incisors using a spectrophotometer as the gold standard, along with RAW mobile calibrated and non-calibrated photos in different light conditions. Materials and methods: A total of 30 dental students participated in the study. CIE L*a*b* values were measured in the middle third of each maxillary right central incisor spectrophotometrically and digitally on RAW mobile dental photos using different light conditions (F-frontal light ; L-lateral light ; D- lateral light with diffusers ; P- polarizing filter on frontal light ; H-hybrid filter as combination of frontal light with polarizing filter and lateral lights with diffusers) with LEDs (light emitting diode) in full power, and with gray card calibration. The obtained results were compared. Results: Mean a* and b* values on calibrated, as well as mean L* values on non- calibrated RAW mobile photos did not significantly differ in different light conditions (P>0.05). CIE L*a*b* values on non- calibrated polarizing RAW mobile photos completely matched the same values obtained using a spectrophotometer on the subject’s maxillary right central incisor (P>0.05). Conclusions: Different light conditions and measuring procedures affected CIE L*a*b* values on RAW mobile photos in this study. Within the limitations, non-calibrated RAW mobile photos using a lightening device with polarizing filters on frontal LED light in standardized conditions can be a useful tool for digital dental shade determination.

dentalna estetika ; boja zuba ; nijanse boja ; dentalna fotografija ; upotreba mobilnog telefona

nije evidentirano

engleski

Assessment of Color Parameters on Maxillary Right Central Incisors Using Spectrophotometer and RAW Mobile Photos in Different Light Conditions

Abstract Objectives: The aim of the study was to compare three color parameters assessed on the maxillary right central incisors using a spectrophotometer as the gold standard, along with RAW mobile calibrated and non-calibrated photos in different light conditions. Materials and methods: A total of 30 dental students participated in the study. CIE L*a*b* values were measured in the middle third of each maxillary right central incisor spectrophotometrically and digitally on RAW mobile dental photos using different light conditions (F-frontal light ; L-lateral light ; D- lateral light with diffusers ; P- polarizing filter on frontal light ; H-hybrid filter as combination of frontal light with polarizing filter and lateral lights with diffusers) with LEDs (light emitting diode) in full power, and with gray card calibration. The obtained results were compared. Results: Mean a* and b* values on calibrated, as well as mean L* values on non- calibrated RAW mobile photos did not significantly differ in different light conditions (P>0.05). CIE L*a*b* values on non- calibrated polarizing RAW mobile photos completely matched the same values obtained using a spectrophotometer on the subject’s maxillary right central incisor (P>0.05). Conclusions: Different light conditions and measuring procedures affected CIE L*a*b* values on RAW mobile photos in this study. Within the limitations, non-calibrated RAW mobile photos using a lightening device with polarizing filters on frontal LED light in standardized conditions can be a useful tool for digital dental shade determination.

Dental Esthetics ; Tooth Color ; Color Shade ; Dental Photography ; Cell Phone Use

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

54 (4)

2020.

353-362

objavljeno

0001-7019

1846-0410

10.15644/asc54/4/2