Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Long-term monitoring of a hybrid SFRC slab on grade using recycled tyre steel fibres (CROSBI ID 287305)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Baricevic, Ana ; Grubor, Martina ; Paar, Rinaldo ; Papastergiou, Panos ; Pilakoutas, Kypros ; Guadagnini, Maurizio Long-term monitoring of a hybrid SFRC slab on grade using recycled tyre steel fibres // Advances in concrete construction, 10 (2020), 6; 547-557. doi: 10.12989/acc.2020.10.6.547

Podaci o odgovornosti

Baricevic, Ana ; Grubor, Martina ; Paar, Rinaldo ; Papastergiou, Panos ; Pilakoutas, Kypros ; Guadagnini, Maurizio

engleski

Long-term monitoring of a hybrid SFRC slab on grade using recycled tyre steel fibres

This paper presents one of the demonstration projects undertaken during the FP7 EU-funded Anagennisi project (Innovative reuse of all tyre components in concrete-2014-2017) on a full-scale (30 m×40 m, thickness: 0.2 m) Steel Fibre Reinforced Concrete (SFRC) slab-on-grade using a blend of manufactured steel fibres (MSF) and Recycled Tyre Steel Fibres (RTSF). The aim of the project was to assess the use of RTSF in everyday construction practice. The Anagennisi partners, Dulex Ltd in collaboration with Gradmont-Gradacac Ltd and University of Zagreb, designed, cast and monitored the long- term shrinkage deformations of the indoor slab- on-grade slab at Gradmont’s precast concrete factory in Gradacac, Bosnia and Herzegovina. A hybrid RTSF mix (20 kg/m3 of MSF+10 kg/m3 of RTSF) was used to comply with the design criteria which included a maximum load capacity of 20 kN/m2. The slab was monitored for one year using surveying equipment and visual inspection of cracks. During the monitoring period, the slab exhibited reasonable deformations (a maximum displacement of 3.3 mm for both, horizontal and vertical displacements) whilst after five years in use, the owners did not report any issues and were satisfied with the construction methodology and materials used. This work confirms that RSTF is a viable and sustainable solution for slab-on- grade applications.

slab-on-grade ; long-term monitoring ; hybrid fibre reinforced concrete

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

10 (6)

2020.

547-557

objavljeno

2287-5301

2287-531X

10.12989/acc.2020.10.6.547

Povezanost rada

Geodezija, Građevinarstvo, Temeljne tehničke znanosti

Poveznice
Indeksiranost