A Laboratory Setup for Testing Frequency Estimation Algorithms Implemented on Real-Time Target (CROSBI ID 697424)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Kunac, Antonio ; Petrovic, Goran ; Despalatovic, Marin ; Jurcevic, Marko A Laboratory Setup for Testing Frequency Estimation Algorithms Implemented on Real-Time Target // 2020 3rd International Colloquium on Intelligent Grid Metrology (SMAGRIMET) / Ivšić, Branimir ; Petrović, Goran ; Dadić, Martin (ur.). Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu, 2020. str. 98-103 doi: 10.23919/smagrimet48809.2020.9264023

Podaci o odgovornosti

Kunac, Antonio ; Petrovic, Goran ; Despalatovic, Marin ; Jurcevic, Marko

engleski

A Laboratory Setup for Testing Frequency Estimation Algorithms Implemented on Real-Time Target

In this paper a low-budget single-phase voltagewaveform simulator based on the NI PCI-6071E DAQ card anddesktop PC with real-time Phar Lap operating system has beenpresented. Program for generating waveforms in accordanceto the IEC standard 61000-4-13, with harmonics of variablefrequency, amplitude and phase, has been implemented in theLabVIEW RT environment. Calibration of DAQ card internalclock has been performed to increase the accuracy of the gener-ated voltage waveform frequency. In order to achieve consistentsystem operation, DAQ card internal temperature sensor hasbeen used to compensate clock frequency drift caused by localambient temperature variations. For verification purposes, oneof algorithms for the frequency estimation based on the linearKalman filter has been deployed to target PC. Experimentalresults in steady-state and dynamics have also been presented.The estimated frequency of the generated signal matches verywell with the values obtained by the digital multimeter used forcalibration procedure.

Real-time systems, Power system harmonics, Calibration, Kalman filters, Frequency estimation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

98-103.

2020.

objavljeno

10.23919/smagrimet48809.2020.9264023

Podaci o matičnoj publikaciji

2020 3rd International Colloquium on Intelligent Grid Metrology (SMAGRIMET)

Ivšić, Branimir ; Petrović, Goran ; Dadić, Martin

Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu

978-953-184-265-5

Podaci o skupu

3rd International Colloquium on Intelligent Grid Metrology (SMAGRIMET 2020)

predavanje

20.10.2020-23.10.2020

Hrvatska; online

Povezanost rada

Elektrotehnika