LSPR-based colorimetric immunosensor for rapid and sensitive 17β-estradiol detection in tap water (CROSBI ID 286932)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Minopoli, Antonio ; Sakač, Nikola ; Lenyk, Bohdan ; Campanile, Raffaele ; Mayer, Dirk ; Offenhäusser, Andreas ; Velotta, Raffaele ; Della Ventura, Bartolomeo
engleski
LSPR-based colorimetric immunosensor for rapid and sensitive 17β-estradiol detection in tap water
The proposed E2 immunosensor was tested in tap water, where no significant cross-reaction signal was detected by similar molecules (testosterone, progesterone, estrone and estriol). The device described here represents a significant improvement of low E2 levels determination in terms of affordability, time and measuring simplicity, making it suitable for environmental applications.
Gold nanoparticlesLocalized surface plasmon resonanceColorimetric immunosensor17β-estradiolPhotochemical immobilization techniqueAntibodies
nije evidentirano