Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Time-dependent variation of ionized calcium in serum samples (CROSBI ID 286861)

Prilog u časopisu | stručni rad | međunarodna recenzija

Perovic, Antonija ; Njire Braticevic, Marina Time-dependent variation of ionized calcium in serum samples // Biochemia medica, 29 (2019), 3; 1-9. doi: 10.11613/BM.2019.030708

Podaci o odgovornosti

Perovic, Antonija ; Njire Braticevic, Marina

engleski

Time-dependent variation of ionized calcium in serum samples

Introduction: The aim of this study was to compare ionized calcium (iCa) concentrations in arterial heparinized blood and venous serum and to investigate time-dependent variation of iCa in serum samples centrifuged and analysed at different times. Materials and methods: Ionized calcium was measured (N = 25) in arterial blood within 20 min after puncture, and in serum within 10 min after centrifugation conducted 30 min after sampling. Effect of time between sampling and centrifugation was examined in three tubes (N = 30) centrifuged 15, 30 and 60 min after sampling, and analysed within 10 min. Effect of time between centrifugation and analysis was investigated in three tubes (N = 31) centrifuged 30 min after sampling and analysed: 0-10, 30-40 and 90-100 min after centrifugation. Ionized calcium was measured on the Siemens RapidLab 348EX analysers. Statistical significance was tested using Wilcoxon test and ANOVA analysis. Clinical significance was judged against reference change values (RCV). Results: No statistically significant difference was found between iCa in arterial blood and serum (P = 0.274). A statistically significant decrease was found: in tubes centrifuged 60 and 15 min after sampling versus 30 min (P = 0.005, P = 0.003) ; and in tubes analysed 30-40 and 90-100 min after centrifugation versus 0-10 min (P = 0.021, P = 0.027). Clinically significant changes were observed: 60 versus 30 min (centrifugation) and 90-100 versus 0-10 and 30-40 min (analysis). Conclusions: Timely analysed arterial blood and serum samples can be used interchangeably. To avoid clinically significant variations, serum tubes should be centrifuged within 30 min after sampling, and analysis should be performed within 30 min after centrifugation.

ionized calcium ; serum ; heparin ; specimen handling ; pre-analytical phase

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

29 (3)

2019.

1-9

objavljeno

1330-0962

1846-7482

10.11613/BM.2019.030708

Povezanost rada

nije evidentirano

Poveznice
Indeksiranost