Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Importance of shear-wave elastography in prediction of Achilles tendon rupture (CROSBI ID 286636)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ivanac, Gordana ; Lemac, Domagoj ; Kosović, Vilma ; Bojanić, Kristina ; Čengić, Tomislav ; Dumić-Čule, Ivo ; Pećina, Marko ; Brkljačić, Boris Importance of shear-wave elastography in prediction of Achilles tendon rupture // International orthopaedics, 45 (2020), 4; 1043-1047. doi: 10.1007/s00264-020-04670-2

Podaci o odgovornosti

Ivanac, Gordana ; Lemac, Domagoj ; Kosović, Vilma ; Bojanić, Kristina ; Čengić, Tomislav ; Dumić-Čule, Ivo ; Pećina, Marko ; Brkljačić, Boris

engleski

Importance of shear-wave elastography in prediction of Achilles tendon rupture

Purpose: It was demonstrated that about 6% of patients with a ruptured Achilles tendon experience the rupture of contralateral tendon in the future ; the aim of this study was to estimate the risk for rupture of contralateral tendon in patients who underwent surgical reconstruction of ruptured Achilles tendon by using subjective questionnaires and shear-wave elastography. Methods: Twenty- four patients who underwent surgical repair of the ruptured Achilles tendon and twelve age-matched healthy controls were examined with ultrasound SWE. Functional outcomes were assessed with American Orthopedic Foot and Ankle Society (AOFAS) scoring system and subjective rating system which we introduced and validated. Results: The elasticity of injured tendon was markedly decreased (by 42%) compared to the contralateral tendon of the patient, as expected. Both AOFAS score and our novel subjective assessment scale positively correlate with ultrasound SWE values in ruptured Achilles tendons. The elasticity of contralateral Achilles tendons in patients was 23% lower than among healthy individuals. Conclusion: Irrespective of the lack of difference in the subjective feeling assessed by AOFAS, the contralateral tendon in the patients with reconstructed Achilles tendon has significantly lower stiffness than healthy individuals. Therefore, contralateral tendons in patients who suffered from rupture are more prone to future ruptures.

Achilles tendon ; Prevention ; Rupture ; Shear wave elastography

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

45 (4)

2020.

1043-1047

objavljeno

0341-2695

1432-5195

10.1007/s00264-020-04670-2

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost