Influence of medium on corrosion and microstructural properties of K110 tool steel for cold work (CROSBI ID 697106)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Brajčinović, Sandra ; Begić Hadžipašić, Anita ; Slokar Benić, Ljerka Influence of medium on corrosion and microstructural properties of K110 tool steel for cold work // Metal 2020, 29th International Conference on Metallurgy and Materials, Conference Proceedings. Brno: METAL 2020, Conference Proceedings / - Ostrava : TANGER Ltd., 2020. str. 816-821 doi: 10.37904/metal.2020.3558

Podaci o odgovornosti

Brajčinović, Sandra ; Begić Hadžipašić, Anita ; Slokar Benić, Ljerka

engleski

Influence of medium on corrosion and microstructural properties of K110 tool steel for cold work

This paper presents the results of testing the corrosion behaviour of K110 tool steel for cold work in industrial emulsion medium (Lenox Band- Ade semi-synthetic oil + water, in a ratio of 1:10), water and 3.5% NaCl medium. Using the method of electrochemical impedance spectroscopy (EIS) and Tafel extrapolation, electrochemical measurements were performed in order to determine the corrosion parameters. After polarization measurements, the surface of the sample was examined with an optical microscope. Tafel extrapolation of the polarization curves revealed that the tested tool steel showed the lowest corrosion rate in the Lenox Band-Ade emulsion medium and the highest in the medium of 3.5% NaCl. The obtained results were confirmed by the method of electrochemical impedance spectroscopy, where the lowest charge transfer resistance was registered in the 3.5% NaCl medium, which indicates the fact that the thinnest oxide layer was formed in tested medium, which has a very weak protective role in the corrosion process. Metallographic analysis of the sample surface after polarization measurements in 3.5% NaCl medium indicates the occurrence of pitting corrosion caused by the action of aggressive chloride ions from the solution, which caused the destruction an already weak passive layer on the metal surface. At the same time, chloride ions from the acid medium attack more aggressively the matrix of the metal base of the tool steel, in contrast to the precipitated carbides on the sample surface.

Tool steel for cold work ; corrosion rate ; impedance ; microstructure

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

816-821.

2020.

objavljeno

10.37904/metal.2020.3558

Podaci o matičnoj publikaciji

Brno: METAL 2020, Conference Proceedings / - Ostrava : TANGER Ltd.

978-80-87294-97-0

2694-9296

Podaci o skupu

29th International Conference on Metallurgy and Materials (METAL 2020)

poster

20.05.2020-22.05.2020

Brno, Češka Republika

Povezanost rada

Metalurgija