Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Critical stress of oval foil winding with epoxy coated insulation determined using measured equivalent modulus of elasticity (CROSBI ID 286350)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Meško, Nina ; Ćućić, Branimir ; Žarko, Damir Critical stress of oval foil winding with epoxy coated insulation determined using measured equivalent modulus of elasticity // Automatika : časopis za automatiku, mjerenje, elektroniku, računarstvo i komunikacije, 61 (2020), 3; 388-395. doi: 10.1080/00051144.2020.1761100

Podaci o odgovornosti

Meško, Nina ; Ćućić, Branimir ; Žarko, Damir

engleski

Critical stress of oval foil winding with epoxy coated insulation determined using measured equivalent modulus of elasticity

In the distribution transformers design oval windings are used due to economic advantages. On the other hand, such windings are more susceptible to radial forces in a short circuit. A diamond dotted paper with an epoxy coating is used in order to increase the stiffness of the winding. Despite that, winding failure may occur during the short circuit, e.g. buckling of inner winding. Because of a very thin foil conductor (typically 0.5–2 mm), the most critical is inner low voltage foil winding which can collapse due to radial forces at stresses far below the elastic limit of conductor material. This paper shows an analytical approach to the calculation of critical stress in inner oval foil winding with epoxy coated insulation. Critical stress was calculated using the equation for free buckling of round winding. Equivalent Young's modulus of elasticity was obtained experimentally from the testing of the sample model loaded with bending force on a tensile test machine. A total of 12 test samples were formed from aluminium foil conductor and diamond dotted paper and cured at the temperature of 105°C. The results were successfully verified on distribution transformers subjected to short circuit withstand tests.

distribution transformer ; short circuit ; critical stress ; oval foil winding ; diamond paper ; Young's modulus of elasticity

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

61 (3)

2020.

388-395

objavljeno

0005-1144

1848-3380

10.1080/00051144.2020.1761100