Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Fluorescent spot test screening for glucose-6- phosphate dehydrogenase deficiency in Dalmatia (CROSBI ID 695954)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Krželj, Vjekoslav ; Balarin, Livio ; Zlodre, Sanja ; Terzić, Janoš ; Jakšić, Jasminka ; Marušić Eugenija ; Petrić Miše, Branka Fluorescent spot test screening for glucose-6- phosphate dehydrogenase deficiency in Dalmatia. 2000. str. 115-115

Podaci o odgovornosti

Krželj, Vjekoslav ; Balarin, Livio ; Zlodre, Sanja ; Terzić, Janoš ; Jakšić, Jasminka ; Marušić Eugenija ; Petrić Miše, Branka

engleski

Fluorescent spot test screening for glucose-6- phosphate dehydrogenase deficiency in Dalmatia

The objective of this study was to determine the prevalence of glucose-6-phosphate dehydrogenase (G-6-PD) deficiency among the population of the Croatian Adriatic Coast, part of the Mediterranean basin. METHODS: The fluorescent spot test was used to screen 2, 726 randomly selected high school students in the Croatian Adriatic coastal area. Fluorescence readings were performed at the beginning and at 3, 6, 10, and 25 min of incubation. Results were classified into the following three groups: bright fluorescence (BF), weak fluorescence (WF), and no fluorescence (NF). All NF and WF samples at 3 min were quantitatively measured using the spectrophotometric method. RESULTS: Twelve persons, 10 boys and 2 girls, were found to be deficient in G-6-PD, rendering a 0.44% prevalence of G-6-PD deficiency. All NF samples at fluorescent spot test were G-6-PD-deficient. WF at 3 min of the incubation period was present in 33 (1.2%) subjects, and only 2 (6%) were true positive. Fluorescence reading at 10 min of incubation omits five (41%) of the G-6-PD deficient samples. CONCLUSIONS: Prevalence of G-6- PD deficiency in the Croatian Adriatic coastal population is 0.44%. Fluorescent spot test for moderate enzyme deficiency is reliable in early fluorescence reading.

G-6-PD deficiency, favism, fluorescent spot test

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

115-115.

2000.

objavljeno

Podaci o matičnoj publikaciji

Podaci o skupu

Europapaediatrics 2000, The UNEPSA and CESP European Congress of Paediatrics

poster

18.03.2000-21.03.2000

Rim, Italija

Povezanost rada

nije evidentirano