Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Test-Retest Reliability of Velocity and Power in the Deadlift and Squat Exercises Assessed by the GymAware PowerTool System (CROSBI ID 284638)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Grgić, Jozo ; Ščapec, Bela ; Pedišić, Željko ; Mikulić, Pavle Test-Retest Reliability of Velocity and Power in the Deadlift and Squat Exercises Assessed by the GymAware PowerTool System // Frontiers in physiology, 11 (2020), 561682, 8. doi: 10.3389/fphys.2020.561682

Podaci o odgovornosti

Grgić, Jozo ; Ščapec, Bela ; Pedišić, Željko ; Mikulić, Pavle

engleski

Test-Retest Reliability of Velocity and Power in the Deadlift and Squat Exercises Assessed by the GymAware PowerTool System

We explored the test-retest reliability of velocity and power assessed by the GymAware PowerTool system (GYM) in the deadlift and squat by simulating a context with and without a familiarization session. Sixteen resistance-trained individuals completed three testing sessions. In all sessions, velocity and power were assessed by the GYM system in the deadlift and squat exercises with loads of 30, 45, 60, 75, and 90% of one-repetition maximum. The consistency of test results between the first session and the second session was considered to represent the reliability with no familiarization session. The consistency of test results between the second session and the third session was considered to represent the reliability with one familiarization session because the first session simulates a familiarization session. Intraclass correlation coefficients (ICCs) ranged 0.63–0.99 in the deadlift, and 0.78–0.99 in the squat. ICCs were higher than 0.75 for 93 and 100% of all deadlift and squat tests, respectively. For velocity and power, standard error of measurement ranged 0.03–0.08 m/s and 20–176 W, respectively. The coefficient of variation ranged 2.2–10.6% for the deadlift and 2.6–6.9% for the squat tests. Except for peak and mean velocity at 30% of 1RM in the squat, we found no significant improvements in reliability with a familiarization session. The test-retest reliability of velocity and power assessed by the GYM system was moderate-to-excellent for the deadlift and good-to-excellent for the squat. Reliability of velocity and power did not seem to improve with a familiarization session.

velocity-based training ; linear position transducer ; movement velocity ; resistance training ; strength

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

11

2020.

561682

8

objavljeno

1664-042X

10.3389/fphys.2020.561682

Povezanost rada

Kineziologija

Poveznice
Indeksiranost