Analytical bias of automated immunoassays for six serum steroid hormones assessed by LC-MS/MS (CROSBI ID 284636)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Debeljak, Željko ; Marković, Ivana ; Šerić, Vatroslav ; Horvat, Vesna ; Mandić, Sanja ; Mandić, Dario ; Lukić, Iva ; Pavela, Jasna Analytical bias of automated immunoassays for six serum steroid hormones assessed by LC-MS/MS // Biochemia medica, 30 (2020), 3; 422-431. doi: 10.11613/bm.2020.030701

Podaci o odgovornosti

Debeljak, Željko ; Marković, Ivana ; Šerić, Vatroslav ; Horvat, Vesna ; Mandić, Sanja ; Mandić, Dario ; Lukić, Iva ; Pavela, Jasna

engleski

Analytical bias of automated immunoassays for six serum steroid hormones assessed by LC-MS/MS

Abstract Introduction There is a growing amount of evidence showing the significant analytical bias of steroid hormone immunoassays, but large number of available immunoassays makes conduction of a single comprehensive study of this issue hardly feasible. Aim of this study was to assess the analytical bias of six heterogeneous immunoassays for serum aldosterone, cortisol, dehydroepiandrosterone sulphate (DHEAS), testosterone, 17-hydroxyprogesterone (OHP) and progesterone using the liquid chromatography coupled to the tandem mass spectrometry (LC- MS/MS). Materials and methods This method comparison study included 49 serum samples. Testosterone, DHEAS, progesterone and cortisol immunoassays were performed on the Abbott Architect i2000SR or Alinity i analysers (Abbott Diagnostics, Chicago, USA). DiaSorin’s Liaison (DiaSorin, Saluggia, Italy) and DIAsource’s ETI-Max 3000 analysers (DIAsource ImmunoAssays, Louvain-La-Neuve, Belgium) were chosen for aldosterone and OHP immunoassay testing, respectively. All immunoassays were evaluated against the LC-MS/MS assay relying on the commercial kit (Chromsystems, Gräfelfing, Germany) and LCMS-8050 analyser (Shimadzu, Kyoto, Japan). Analytical biases were calculated and method comparison was conducted using weighted Deming regression analysis. Results Depending on the analyte and specific immunoassay, mean relative biases ranged from -31 to + 137%. Except for the cortisol, immunoassays were positively biased. For none of the selected steroids slope and intercept 95% confidence intervals simultaneously contained 0 and 1, respectively. Conclusions Evaluated immunoassays failed to satisfy requirements for methods’ comparability and produced significant analytical biases in respect to the LC-MS/MS assay, especially at low concentrations.

steroid hormone ; immunoassay ; bias ; LC-MS/MS ; method comparison

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

30 (3)

2020.

422-431

objavljeno

1330-0962

10.11613/bm.2020.030701

Povezanost rada

Interdisciplinarne prirodne znanosti, Kemija, Kliničke medicinske znanosti