Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

An optimized sample preparation and analysis method for the determination of polycyclic aromatic hydrocarbons and polychlorinated biphenyls in the atmospheric bulk deposition samples (CROSBI ID 284469)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Šimić, Iva ; Mendaš, Gordana ; Pehnec, Gordana An optimized sample preparation and analysis method for the determination of polycyclic aromatic hydrocarbons and polychlorinated biphenyls in the atmospheric bulk deposition samples // Journal of Chromatography A, 1633 (2020), 461599, 11. doi: 10.1016/j.chroma.2020.461599

Podaci o odgovornosti

Šimić, Iva ; Mendaš, Gordana ; Pehnec, Gordana

engleski

An optimized sample preparation and analysis method for the determination of polycyclic aromatic hydrocarbons and polychlorinated biphenyls in the atmospheric bulk deposition samples

A method based on solid phase extraction (SPE), gas chromatography tandem mass spectrometry (GC-MS/MS) and gas chromatography with electron capture detector (GC-ECD) was developed for the determination of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs) in atmospheric deposition samples. Six indicator PCB congeners were analysed by GC-ECD equipped with two micro electron-capture detectors and two gas chromatographic columns, while 12 PAH compounds were analysed by GC-MS/MS. Solid phase extraction on silica sorbent proved suitable for accumulation of PAHs and PCBs from deposited matters. The extraction procedure was based by passing the whole sample volume through a silica cartridge with dichloromethane and n-hexane as the eluting solvents. Two different performances of a bulk collector were compared. The method was validated using field total deposited samples collected monthly over a year by bulk method at an urban background station in Zagreb, Croatia. The levels and occurrence of PCBs corresponded to global environmental pollution, with the deposition rates of ∑6PCBs between 6 - 28 ng m−2 d−1. The deposition rates of ∑12PAHs varied between 132 and 714 ng m−2 d−1 during the warm period, whereas it achieved a significantly higher range of 171 to 1069 ng m−2 d−1 in the cold period.

bulk ; PAH ; PCB ; total deposited matter

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

1633

2020.

461599

11

objavljeno

0021-9673

1873-3778

10.1016/j.chroma.2020.461599

Povezanost rada

Javno zdravstvo i zdravstvena zaštita, Kemija

Poveznice
Indeksiranost