Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Proposal and techno-economic analysis of a novel system for waste heat recovery and water saving in coal-fired power plants: A case study (CROSBI ID 284361)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Tan, Houzhang ; Cao, Ruijie ; Wang, Shunsen ; Wang, Yibin ; Deng, Shuanghui ; Duić, Neven Proposal and techno-economic analysis of a novel system for waste heat recovery and water saving in coal-fired power plants: A case study // Journal of cleaner production, 281 (2021), 124372, 5. doi: 10.1016/j.jclepro.2020.124372

Podaci o odgovornosti

Tan, Houzhang ; Cao, Ruijie ; Wang, Shunsen ; Wang, Yibin ; Deng, Shuanghui ; Duić, Neven

engleski

Proposal and techno-economic analysis of a novel system for waste heat recovery and water saving in coal-fired power plants: A case study

A novel system, which systematically recover waste heat and reduce water consumption in coal-fired power plants, is proposed in this paper. Critical components of the system are two fluorine plastic heat exchangers (FHEs) located downstream and upstream of WFGD scrubber, and condensate and feed water extracted from the regenerative heater (RH) act as coolants, respectively. All recovered heat is utilized directly with no heat pump required. A thermodynamic model, where the steam/water cycle is coupled with the exhaust flue gas flow, is built to assess the performance of the system, and the economic analysis is involved to further explore the feasibility. The simulation is conducted based on parameters of a 1000 MW coal-fired power unit in operation, while coal and water saving rates, payback period, and net present value (NPV) are used as criteria in the assessment. The results show that the system can significantly reduce coal and water consumption of the reference power unit. The temperature of condensate and feed water extraction determines the techno-economic performance of the low- and high-temperature FHEs (LFHE and HFHE), respectively. Lower condensate temperature and higher feed water extraction temperature are more beneficial. Compared with the case of only LFHE, integrating HFHE into the system will increase the overall coal and water saving rates obviously, although the performance of LFHE is weakened. All layouts of the system presented in this paper are techno-economically feasible, and the layout in Case 4 where HFHE is installed in parallel with RH6 is the optimal one. Coal and water saving rates, and NPV of the optimal layout are up to 4.11 g/kWh, 95 t/h, and 102, 739, 000 RMB, respectively, while the payback period is less than 4 y. Application of this system is beneficial to mitigating the environmental problems caused by coal-fired power generation.

waste heat recovery ; coal consumption ; water saving ; coal-fired power plant ; flue gas ; techno-economic analysis

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

281

2021.

124372

5

objavljeno

0959-6526

1879-1786

10.1016/j.jclepro.2020.124372

Povezanost rada

Strojarstvo

Poveznice
Indeksiranost