Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Experimental and optimization study on NOx emissions of a full-scale industrial pulverized coal combustor with pre-combustion chamber (CROSBI ID 694882)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Wang, Xuebin ; Xu, Xinwei ; Tan, Houzhang ; Mikulčić, Hrvoje ; Vujanović, Milan Experimental and optimization study on NOx emissions of a full-scale industrial pulverized coal combustor with pre-combustion chamber // Digital Proceedings of 4th South East European Conference on Sustainable Development of Energy, Water and Environment Systems - SEE SDEWES / Ban, Marko (ur.). Zagreb, 2020

Podaci o odgovornosti

Wang, Xuebin ; Xu, Xinwei ; Tan, Houzhang ; Mikulčić, Hrvoje ; Vujanović, Milan

engleski

Experimental and optimization study on NOx emissions of a full-scale industrial pulverized coal combustor with pre-combustion chamber

The increasingly stringent emission standards in China lead to lower emission requirements on the coal-fired industrial boilers, and it is difficult for the existing industrial boiler to meet the emission standards without the selective catalytic reduction (SCR) technology. This paper presents a new type of low-NOx coal- fired industrial burner. The effects of primary air ratio, secondary air ratio, swirl vane angle, FGR ratio and OFA ratio on the NOx emission. The results show that the NOx concentration gradually increases as the primary air ratio increases from 7.8% to 8.5%. As the inner secondary air ratio increases from 0.67 to 1.32, the NOx concentration gradually increases. The amount of NOx concentration decreases first and then increases with the angle of swirl vane increases from 30 ° to 60 °. The OFA ratio has a feeble influence on NOx, and the overall trend is to decrease first and then increase with increasing OFA ratio. The NOx concentration decreases and and the extent of decrease slows down as the FGR ratio increases from 0 to 13.3%. The NOx emission is 175 mg/m3 (9% O2) while the carbon in fly ash is 14.94 % and the boiler thermal efficiency is 91.7%.

NOx emission ; FGR ratio ; Pre-combustion chamber ; Low NOx burner ; Industrial boiler

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

162

2020.

objavljeno

Podaci o matičnoj publikaciji

Digital Proceedings of 4th South East European Conference on Sustainable Development of Energy, Water and Environment Systems - SEE SDEWES

Ban, Marko

Zagreb:

Podaci o skupu

4th South East Europe Conference on Sustainable Development of Energy, Water and Environment Systems (4th SEE SDEWES Conference)

predavanje

28.06.2020-02.07.2020

Sarajevo, Bosna i Hercegovina

Povezanost rada

Strojarstvo