Excess heat utilization combined with thermal storage integration in district heating systems using renewables (CROSBI ID 284134)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Doračić, Borna ; Grozdek, Marino ; Pukšec, Tomislav ; Duić, Neven Excess heat utilization combined with thermal storage integration in district heating systems using renewables // Thermal science, 24 (2020), 6A; 3673-3684. doi: 10.2298/TSCI200409286D

Podaci o odgovornosti

Doračić, Borna ; Grozdek, Marino ; Pukšec, Tomislav ; Duić, Neven

engleski

Excess heat utilization combined with thermal storage integration in district heating systems using renewables

District heating systems already play an important role in increasing the sustainability of the heating sector and decreasing its environmental impact. However, a high share of these systems is old and inefficient and therefore needs to change towards the 4th generation district heating, which will incorporate various energy sources, including renewables and excess heat of different origins. Especially excess heat from industrial and service sector facilities is an interesting source since its potential has already been proven to be highly significant, with some researches showing that it could cover the heat demand of the entire residential and service sector in Europe. However, most analysis of its utilization in district heating are not done on the hourly level, therefore not taking into account the variability of its availability. For that reason, the main goal of this work was to analyse the integration of industrial excess heat into the district heating system consisting of different configurations, including the zero fuel cost technologies like solar thermal. Furthermore, cogeneration units were a part of every simulated configuration, providing the link to the power sector. Excess heat was shown to decrease the operation of peak load boiler and cogeneration, that way decreasing the costs and environmental effect of the system. However, since its hourly availability differs from the heat demand, thermal storage needs to be implemented in order to increase the utilization of this source. The analysis was performed on the hourly level in the energyPRO software.

district heating ; excess heat ; hourly analysis ; energyPRO ; thermal storage