Evaluation of Platelet count and Platelet Function Analyzer - 100 testing for prediction of platelet transfusion following coronary bypass surgery (CROSBI ID 283355)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Bogdanić, Dejana ; Bogdanić, Nikolina ; Karanović, Nenad
engleski
Evaluation of Platelet count and Platelet Function Analyzer - 100 testing for prediction of platelet transfusion following coronary bypass surgery
Platelet transfusion are commonly administered to treat bleeding in cardiac surgery. The aim of this study was to compare platelet (PLT) count and values of collagen adenosine diphosphate closure time (cADP-CT) measured by Platelet Function Analyzer (PFA) for prediction of PLT transfusion therapy following coronary bypass surgery. For this prospective observational study, 66 patients scheduled for coronary artery bypass grafting (CABG) who received early PLT transfusions (within 60 min after the operation) were enrolled. To assess changes in platelets, count and function, two time points were selected: 15 min before and 30-60 min after the end of PLT transfusion. The patients were divided into transfused and non- transfused with further PLT in the 48 h postoperatively. We used the receiver operating characteristics (ROC) curve to investigate whether the PLT count and cADP-CT values were predictors of PLT transfusion.
Platelet transfusion ; cardiac surgery ; clinical laboratory tests
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
80 (4)
2020.
296-302
objavljeno
0036-5513
1502-7686