Pretražite po imenu i prezimenu autora, mentora, urednika, prevoditelja

Napredna pretraga

Pregled bibliografske jedinice broj: 1076646

Corrigendum to: Analytical evaluation of the new Seal Autoanalyzer 3 High Resolution for urinary


Vidranski, Valentina; Franceschi, Maja; Krilić, Dražena; Jukić, Tomislav; Mihaljević, Ivan; Kusić, Zvonko
Corrigendum to: Analytical evaluation of the new Seal Autoanalyzer 3 High Resolution for urinary // Biochemia medica, 29 (2019), 3; 621-621 doi:10.11613/bm.2019.031201 (recenziran, članak, znanstveni)


CROSBI ID: 1076646 Za ispravke kontaktirajte CROSBI podršku putem web obrasca

Naslov
Corrigendum to: Analytical evaluation of the new Seal Autoanalyzer 3 High Resolution for urinary
(Corrigendum to: Analytical evaluation of the new Seal Autoanalyzer 3 High Resolution for urinary iodine determination)

Autori
Vidranski, Valentina ; Franceschi, Maja ; Krilić, Dražena ; Jukić, Tomislav ; Mihaljević, Ivan ; Kusić, Zvonko

Izvornik
Biochemia medica (1330-0962) 29 (2019), 3; 621-621

Vrsta, podvrsta i kategorija rada
Radovi u časopisima, članak, znanstveni

Ključne riječi
colorimetry ; iodine ; method evaluation ; urine

Sažetak
Abstract Introduction The aim of the study was to evaluate the analytical performance of the new colorimetric, automatic analyser, Seal AutoAnalyzer 3 High Resolution (Seal AA3 HR) (Seal Analytical, Wisconsin, USA) for urinary iodine measurement. Materials and methods This study included testing of several analytical features of the method involving: imprecision (within-run %CVr, between-run %CVb and total laboratory precision %CVl), measurement uncertainty, carryover, linearity and method comparison, with 70 urine samples including the measuring range (20 - 700 µg/L). Results Within-run, %CVb and %CVl of two control levels were 2.03% and 3.04%, 0.51% and 2.61%, and 2.09% and 4.01%, respectively. Carryover effect was less than 1%. The linearity was good in the range of urinary iodine values between 60 and 500 µg/L (R2 = 0.99). Good agreement of urinary iodine values was found between manual technique and Seal AA3 HR, using Passing-Bablok regression (y = 7.84 (- 3.00 to 15.29) + 0.95 (0.90 to 1.00) x) and Blant-Altman test. Cusum test for linearity indicates that there is no significant deviation from linearity (P > 0.1). Conclusions The obtained results proved excellent precision, reproducibility and linearity, comparable to the already used, manual method. The New Seal AA3 HR automatic analyser is acceptable for urinary iodine measurement with very good analytical characteristics and can be used for urinary iodine epidemiological studies of the Croatian population.

Izvorni jezik
Engleski



POVEZANOST RADA


Citiraj ovu publikaciju

Vidranski, Valentina; Franceschi, Maja; Krilić, Dražena; Jukić, Tomislav; Mihaljević, Ivan; Kusić, Zvonko
Corrigendum to: Analytical evaluation of the new Seal Autoanalyzer 3 High Resolution for urinary // Biochemia medica, 29 (2019), 3; 621-621 doi:10.11613/bm.2019.031201 (recenziran, članak, znanstveni)
Vidranski, V., Franceschi, M., Krilić, D., Jukić, T., Mihaljević, I. & Kusić, Z. (2019) Corrigendum to: Analytical evaluation of the new Seal Autoanalyzer 3 High Resolution for urinary. Biochemia medica, 29 (3), 621-621 doi:10.11613/bm.2019.031201.
@article{article, year = {2019}, pages = {621-621}, DOI = {10.11613/bm.2019.031201}, keywords = {colorimetry, iodine, method evaluation, urine}, journal = {Biochemia medica}, doi = {10.11613/bm.2019.031201}, volume = {29}, number = {3}, issn = {1330-0962}, title = {Corrigendum to: Analytical evaluation of the new Seal Autoanalyzer 3 High Resolution for urinary}, keyword = {colorimetry, iodine, method evaluation, urine} }
@article{article, year = {2019}, pages = {621-621}, DOI = {10.11613/bm.2019.031201}, keywords = {colorimetry, iodine, method evaluation, urine}, journal = {Biochemia medica}, doi = {10.11613/bm.2019.031201}, volume = {29}, number = {3}, issn = {1330-0962}, title = {Corrigendum to: Analytical evaluation of the new Seal Autoanalyzer 3 High Resolution for urinary iodine determination}, keyword = {colorimetry, iodine, method evaluation, urine} }

Časopis indeksira:


  • Current Contents Connect (CCC)
  • Web of Science Core Collection (WoSCC)
    • Science Citation Index Expanded (SCI-EXP)
    • SCI-EXP, SSCI i/ili A&HCI
  • Scopus
  • MEDLINE


Citati





    Contrast
    Increase Font
    Decrease Font
    Dyslexic Font