Final report on key comparison EURAMET.M.P-K1.c in the range 0.7 MPa to 7.0 MPa of gas gauge pressure (CROSBI ID 282209)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Aykurt, Altıntaş ; Ilknur, Koçaş ; Yasin, Durgut ; Joseph, Bartolo ; Mercede, Bergoglio ; Lovorka, Grgec Bermanec ; Alen, Bošnjaković ; Sanja, Burzić ; Antoine, Condereys ; Miruna, Dobre et al. Final report on key comparison EURAMET.M.P-K1.c in the range 0.7 MPa to 7.0 MPa of gas gauge pressure // Metrologia, Volume 57 (2020), Number 1A 07022, 43. doi: 10.1088/0026-1394/57/1A/07022

Podaci o odgovornosti

Aykurt, Altıntaş ; Ilknur, Koçaş ; Yasin, Durgut ; Joseph, Bartolo ; Mercede, Bergoglio ; Lovorka, Grgec Bermanec ; Alen, Bošnjaković ; Sanja, Burzić ; Antoine, Condereys ; Miruna, Dobre ; Peter, Farar ; Paul, Hetherington ; Nieves, Medina ; Wladimir, Sabuga ; Oliver, Ott ; Thomas, Konczak ; Ion, Sandu ; Janez, Setina ; Dietmar, Steindl ; Csilla, Vámossy ; Bernard, Waller ; Christian, Wuethrich ; Adam, Brzozowski ; Jan, van Geel ; Sari, Saxhol ; Fredrik, Arrhén ;

engleski

Final report on key comparison EURAMET.M.P-K1.c in the range 0.7 MPa to 7.0 MPa of gas gauge pressure

A EURAMET key comparison of the national pressure standards in the range 0.7 MPa to 7.0 MPa of gas gauge pressure was carried out. The circulation of the transfer standard began in November 2011 and lasted until November 2016. The measurand of the comparison was the effective area of the piston-cylinder assembly determined by gauge pressure measurements in the range from 0.7 MPa to 7.0 MPa. As the comparison reference value, the weighted mean of the results of the laboratories with primary pressure standards was used. With this reference value, all the participants who delivered the results demonstrated equivalence respective to the reference value within expanded uncertainties (k = 2) on all the range. The results of this comparison were linked to CCM key comparison CCM.P-K1.c. Also in relation to the reference values of CCM.P- K1.c, all participants demonstrated agreement within expanded uncertainties (k = 2) at all pressure points.

gas pressure, intercomparison

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

Volume 57

2020.

Number 1A 07022

43

objavljeno

0026-1394

1681-7575

10.1088/0026-1394/57/1A/07022

Povezanost rada

Fizika, Interdisciplinarne tehničke znanosti, Strojarstvo

Poveznice
Indeksiranost