Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Hand monitoring in nuclear medicine departments in Croatia – first results (CROSBI ID 281549)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Surić Mihić, Marija ; Bernat, Robert ; Šiško, Jerko ; Vojnić Kortmiš, Maja ; Pavelić, Luka ; Prlić, Ivica ; Mišak, Nikolina Hand monitoring in nuclear medicine departments in Croatia – first results // Nuclear technology & radiation protection, 35 (2020), 1; 82-86. doi: 10.2298/NTRP2001082S

Podaci o odgovornosti

Surić Mihić, Marija ; Bernat, Robert ; Šiško, Jerko ; Vojnić Kortmiš, Maja ; Pavelić, Luka ; Prlić, Ivica ; Mišak, Nikolina

hrvatski

Hand monitoring in nuclear medicine departments in Croatia – first results

Individual hand monitoring for workers who manipulate unsealed radioactive sources in nuclear medicine is a necessity and the results can serve as the base for optimization processes.We performed an analysis of individual hand doses for medical staff preparing and applying radiopharmaceuticals (99mTc, 123I, 201Tl, 131I, or 125I) in three Croatian clinical hospitals, for a period of one year since extremity monitoring be came legally mandatory in Croatia. The majority of annual hand doses for workers were be low or slightly above 150 mSv per year with only a few workers exceeding the annual dose limit of 500 mSv. The analysis confirmed that the radiation protection expert's role in an individual monitoring programme and personal dosimetry is crucial in order to achieve the optimal radiation protection of workers.

hands monitoring ; nuclear medicine ; Hp(0, 07) ; occupational exposure ; equivalent dose to hands ; ring dosimetry

nije evidentirano

engleski

Hand monitoring in nuclear medicine departments in Croatia – first results

nije evidentirano

hands monitoring ; nuclear medicine ; Hp(0, 07) ; occupational exposure ; equivalent dose to hands ; ring dosimetry

nije evidentirano

Podaci o izdanju

35 (1)

2020.

82-86

objavljeno

1451-3994

1452-8185

10.2298/NTRP2001082S

Trošak objave rada u otvorenom pristupu

Povezanost rada

Fizika, Interdisciplinarne prirodne znanosti, Javno zdravstvo i zdravstvena zaštita

Poveznice
Indeksiranost