Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Evaluation of Synthetic Ceramics as Compression Resistant Matrix to Promote Osteogenesis of Autologous Blood Coagulum Containing Recombinant Human Bone Morphogenetic Protein 6 in Rabbit Posterolateral Lumbar Fusion Model (CROSBI ID 280949)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Štoković, Nikola ; Ivanjko, Natalija ; Pećin, Marko ; Erjavec, Igor ; Karlović, Sven ; Smajlović, Ana ; Capak, Hrvoje ; Milošević, Milan ; Bubić-Špoljar, Jadranka ; Vnuk, Dražen et al. Evaluation of Synthetic Ceramics as Compression Resistant Matrix to Promote Osteogenesis of Autologous Blood Coagulum Containing Recombinant Human Bone Morphogenetic Protein 6 in Rabbit Posterolateral Lumbar Fusion Model // Bone (New York, N.Y.), 140 (2020), 115544, 11

Podaci o odgovornosti

Štoković, Nikola ; Ivanjko, Natalija ; Pećin, Marko ; Erjavec, Igor ; Karlović, Sven ; Smajlović, Ana ; Capak, Hrvoje ; Milošević, Milan ; Bubić-Špoljar, Jadranka ; Vnuk, Dražen ; Matičić, Dražen ; Oppermann, Hermann ; Sampath, T. Kuber, Vukičević, Slobodan

engleski

Evaluation of Synthetic Ceramics as Compression Resistant Matrix to Promote Osteogenesis of Autologous Blood Coagulum Containing Recombinant Human Bone Morphogenetic Protein 6 in Rabbit Posterolateral Lumbar Fusion Model

Posterolateral lumbar fusion (PLF) is a commonly performed surgical procedure for the treatment of pathological conditions of the lumbosacral spine. In the present study, we evaluated an autologous bone graft substitute (ABGS) containing rhBMP6 in autologous blood coagulum (ABC) and synthetic ceramics used as compression resistant matrix (CRM) in rabbit PLF model. In the pilot PLF rabbit experiment, we tested four different CRMs (BCP 500-1700 μm, BCP 1700-2500 μm and two different TCP in the form of slabs) which were selected based on achieving uniform ABC distribution. Next, ABGS implants composed of 2.5 mL ABC with 0.5 g ceramic particles (TCP or BCP (TCP/HA 80/20) of particle size 500-1700 μm) and 125 μg rhBMP6 (added to blood or lyophilized on bioceramics) were placed bilaterally between transverse processes of the lumbar vertebrae (L5-L6) following exposition and decortication in 12 New Zealand White Rabbits observed for 7 weeks following surgery. Spinal fusion outcome was analysed by μCT, palpatory segmental mobility testing and selected specimens were either tested biomechanically (three-point bending test) and/or processed histologically. The total fusion success rate was 90.9% by both μCT analyses and by palpatory segmental mobility testing. The volume of newly formed bone between experimental groups in of TCP or BCP ceramics and the method of rhBMP6 application was comparable. The newly formed bone and ceramic particles integrated with the transverse processes on histological sections resulting in superior biomechanical properties. The results were retrospectively found superior to allograft devitalized mineralized bone as a CRM as reported previously in rabbit PLF.

Posterolateral lumbar fusion (PLF) ; BMP6 ; synthetic ceramics ; autologous bone graft substitute (ABGS) ; BMP carrier ; autologous blood coagulum

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

140

2020.

115544

11

objavljeno

8756-3282

1873-2763

Povezanost rada

Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Veterinarska medicina

Indeksiranost