Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Potential benefit of retrospective use of neutron monitors in improving ionising radiation exposure assessment on international flights: issues raised by neutron passive dosimeter measurements and EPCARD simulations during sudden changes in solar activity (CROSBI ID 280383)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Poje Sovilj, Marina ; Vuković, Branko ; Radolić, Vanja ; Miklavčić, Igor ; Stanić, Denis Potential benefit of retrospective use of neutron monitors in improving ionising radiation exposure assessment on international flights: issues raised by neutron passive dosimeter measurements and EPCARD simulations during sudden changes in solar activit // Arhiv za higijenu rada i toksikologiju, 71 (2020), 152-157. doi: 10.2478/aiht-2020-71-3403

Podaci o odgovornosti

Poje Sovilj, Marina ; Vuković, Branko ; Radolić, Vanja ; Miklavčić, Igor ; Stanić, Denis

engleski

Potential benefit of retrospective use of neutron monitors in improving ionising radiation exposure assessment on international flights: issues raised by neutron passive dosimeter measurements and EPCARD simulations during sudden changes in solar activity

Since air transport became more accessible, more and more people have been exposed to ionising radiation of cosmic origin. Measuring the neutron dose equivalent is a good approximation of total ambient dose equivalent, as neutrons carry about 50 % of the dose at flight altitudes. The aim of our study was to compare our measurements of the neutron component of secondary cosmic radiation dose, taken with passive dosimeters, with the data obtained from a simulation generated by EPCARD software, which is common in assessing flight crew exposure to ionising radiation. We observed deviations (both above and below) from the expected proportion of the neutron component (between 40 and 80 %), which pointed to certain issues with actual passive dosimeter measurement and the EPCARD simulation. The main limitation of the dosimeter are large uncertainties in high energy neutron response, which may result in underestimation of neutron dose equivalent. The main drawback of the software simulation is monthly averaging of solar potential in calculations, which can neglect sporadic high energy events. Since airlines worldwide almost exclusively use software (due to costs and convenience) to estimate the dose received by their crew, it is advisable to retrospectively recalculate the dose taking into account neutron monitor readings when solar activity changes.

aviation route doses ; cosmic radiation ; EPCARD ; nuclear track-etched detector ; solar activity

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

71

2020.

152-157

objavljeno

0004-1254

1848-6312

10.2478/aiht-2020-71-3403

Povezanost rada

Fizika

Poveznice
Indeksiranost