Basis of Guidelines for Structural Design and Thermal Assessment of Buildings with Hybrid CLT-Glass Elements (CROSBI ID 279641)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Perković, Nikola ; Rajčić, Vlatka ; Bedon, Chiara ; Barbalić, Jure ; Žarnić, Roko Basis of Guidelines for Structural Design and Thermal Assessment of Buildings with Hybrid CLT-Glass Elements // International journal of structural glass and advanced materials research, 4 (2020), 1; 97-113. doi: 10.3844/sgamrsp.2020.97.113

Podaci o odgovornosti

Perković, Nikola ; Rajčić, Vlatka ; Bedon, Chiara ; Barbalić, Jure ; Žarnić, Roko

engleski

Basis of Guidelines for Structural Design and Thermal Assessment of Buildings with Hybrid CLT-Glass Elements

Facade elements are known to represent a building component with multiple performance parameters to satisfy. Among others, “advanced facades” take advantage from hybrid solutions, like the assemblage of laminated materials. In addition to enhanced mechanical properties that are typical of optimally composed hybrid structural components, these systems are energy efficient, durable and offer lightening comfort and optimal thermal performance. This is the case of the structural solution developed in joint research efforts of University of Zagreb and University of Ljubljana, within the Croatian VETROLIGNUM project. The design concept involves the mechanical interaction of timber and glass load-bearing members, without sealing or glued glass-to-timber surfaces. Laminated glass infilled timber frames are in fact recognized as a new generation of structural members with relevant load-carrying capacity (and especially the enhancement of earthquake resistance of framed systems), but also energy-efficient and cost-effective solutions. In this paper, brief guidelines for the optimal structural design of glass infilled Cross-Laminated Timber (CLT) framed systems are presented. A special focus is then dedicated to the thermal performance assessment of these innovative CLT-glass facade modules under ordinary operational conditions. Finite Element numerical models of single elements are developed to reproduce a full-size mock-up building. The actual thermal performance is thus carried out with the support of continuous ambient records. The numerical results show that the CLT-glass composite facade system can be efficient and offer performances, in line with national and European standards requirements.

Cross-Laminated Timber (CLT) ; Laminated Glass ; hybrid Facade Element ; Design Guidelines ; Thermal Performance

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

4 (1)

2020.

97-113

objavljeno

2616-4507

10.3844/sgamrsp.2020.97.113

Povezanost rada

Građevinarstvo

Poveznice