Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Verification of the Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) reference values in Croatian children and adolescents (CROSBI ID 279564)

Prilog u časopisu | stručni rad | međunarodna recenzija

Zrinski Topic, Renata ; Leniček Krleža, Jasna Verification of the Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) reference values in Croatian children and adolescents // Biochemia medica, 30 (2020), 2; 1-8. doi: 10.11613/BM.2020.020710

Podaci o odgovornosti

Zrinski Topic, Renata ; Leniček Krleža, Jasna

engleski

Verification of the Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) reference values in Croatian children and adolescents

Introduction The aim of this study was to examine whether the Canadian Laboratory Initiative on Paediatric Reference Intervals (CALIPER) could be applied to Croatian children and adolescents. Materials and methods A total of 295 outpatient healthy children and adolescents of age 1 to 18 were selected using the direct a posteriori sampling method. According to current guidelines, 20 samples were tested for each of a total of 51 reference intervals for ferritin, cortisol, dehydroepiandrosterone sulfate, follicle stimulating hormone, lutein stimulating hormone, prolactin, progesterone, sex hormone binding globulin, thyroid stimulating hormone, total testosterone, total thyroxine and total triiodothyronine. Serum samples were analysed on the Beckman Coulter DxI600 immunoassay analyser by chemiluminescence immunoassay method. A reference interval was adopted if < 10% of the results fall outside CALIPER reference interval range. For analytes in which this criterion is not met in the first set of samples, a new set of 20 samples were collected. Results After the first set of measurements, 96% of all tested reference intervals were adopted for use. The additional sets of 20 reference subjects were tested for only two reference intervals ; follicle stimulating hormone for female aged 1 to 9 years, and irrespective of the gender, sex hormone binding globulin for children aged 8 to 11 years. All results of additional samples were within the specified interval limits. Conclusions CALIPER reference intervals for ferritin and 11 hormones defined for Beckman Coulter DxI600 immunoassay analyser can be implemented into the Croatian laboratories and clinical practice.

hormone ; immunoassay ; paediatric ; reference value

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

30 (2)

2020.

1-8

objavljeno

1330-0962

1846-7482

10.11613/BM.2020.020710

Povezanost rada

Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Integrativna bioetika (prirodne, tehničke, biomedicina i zdravstvo, biotehničke, društvene, humanističke znanosti), Kliničke medicinske znanosti

Poveznice
Indeksiranost