On calculated and actual energy savings from thermal building renovations – long term field evaluation of multifamily buildings (CROSBI ID 279027)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Cholewa, Tomasz ; Balaras, Constantinos A. ; Nižetić, Sandro ; Siuta-Olcha, Alicja On calculated and actual energy savings from thermal building renovations – long term field evaluation of multifamily buildings // Energy and buildings, 223 (2020), 1-10. doi: 10.1016/j.enbuild.2020.110145

Podaci o odgovornosti

Cholewa, Tomasz ; Balaras, Constantinos A. ; Nižetić, Sandro ; Siuta-Olcha, Alicja

engleski

On calculated and actual energy savings from thermal building renovations – long term field evaluation of multifamily buildings

This work presents the results from a field study that collected data on actual operational energy over several heating seasons, from 11 similar multifamily buildings in Poland. All buildings were thermally renovated by insulating their envelope, while for some of them the works were completed by a hydraulic rebalance of their heating system. The modernization activities were implemented with a different sequence. For another group of buildings, the hydraulic balancing of the heating system was not performed after the envelope thermal renovation. This offered an excellent opportunity to compare the actual energy performance of the renovated buildings and quantify the achieved energy savings resulting from different practices. Energy audits were performed in all buildings in order to calculate the energy use of the buildings before and after the renovations. These estimates were then compared with the actual energy savings from the monitored energy use for all renovated buildings. Accordingly, the actual energy savings range between 8.8% and 74.8% of calculated energy savings, depending on the different renovations. The actual payback time for the analysed modernization actions was longer than the calculated one, ranging between 3.1 and 104.8 heating seasons.

energy audit ; building energy retrofit ; thermal renovations ; hydraulic balancing ; energy savings ; energy efficiency ; energy performance gap ; multi-family buildings