Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Short-Term Measurement of Indoor Radon Concentration in Northern Croatia (CROSBI ID 276855)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Siročić Ptiček, Anita ; Stanko, Davor ; Sakač, Nikola ; Dogančić, Dragana ; Trojko Tomislav Short-Term Measurement of Indoor Radon Concentration in Northern Croatia // Applied sciences (Basel), 10 (2020), 7; 2341, 13. doi: 10.3390/app10072341

Podaci o odgovornosti

Siročić Ptiček, Anita ; Stanko, Davor ; Sakač, Nikola ; Dogančić, Dragana ; Trojko Tomislav

engleski

Short-Term Measurement of Indoor Radon Concentration in Northern Croatia

(1) Background: Radon concentrations in the environment are generally very low. However, radon concentrations can be high indoors and can cause some serious health issues. The main source of indoor radon (homes, buildings and other residential objects) can be soil under the house, while other sources can be construction materials, groundwater and natural gas. Radon accumulates mainly in the lower levels of the buildings (especially low-ventilated underground levels and basements). (2) Methods: in this paper, we have measured the indoor radon concentrations at 15 locations in various objects (basements and ground floor/1st floor rooms) in the area of northern Croatia. (3) Results: the results show a higher concentration of radon in the basement area in comparison to values measured in the ground floor and first-floor rooms. The arithmetic mean (AM) and geometric mean (GM) of basement rooms were 70.9 ± 38.8 Bq/m3 and 61.2 ± 2.2 Bq/m3 compared to ground floor and first-floor rooms 42.5 ± 30.8 Bq/m3 and 32.8 ± 2.9 Bq/m3, respectively. (4) Conclusions: results obtained (AM and GM values) are within the maximal allowed values (300 Bq/m3) according to the Euroatom Directive. However, there are periods when maximum radon concentration exceeds 300 Bq/m3. Indoor radon concentrations vary with the occupancy of the rooms and it is evident that the ventilation has significant effect on the reduction of concentration.

radon concentrations ; environment ; indoor radon measurements ; ventilation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

10 (7)

2020.

2341

13

objavljeno

2076-3417

10.3390/app10072341

Trošak objave rada u otvorenom pristupu

Povezanost rada

Geofizika, Geologija, Interdisciplinarne tehničke znanosti, Kemijsko inženjerstvo, Temeljne tehničke znanosti

Poveznice
Indeksiranost