Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Preliminary Characterization of Capacitive Intrabody Communication Channel under Implantable-Like Conditions (CROSBI ID 688802)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Lučev Vasić, Željka ; Cifrek, Mario ; Gao, Yueming ; Du, Min Preliminary Characterization of Capacitive Intrabody Communication Channel under Implantable-Like Conditions // 2020 IEEE International Instrumentation and Measurement Technology Conference Proceedings / Rapuano, Sergio ; Van Moer, Wendy ; Vasic, Darko (ur.). Piscataway (NJ): Institute of Electrical and Electronics Engineers (IEEE), 2020. str. 1-5 doi: 10.1109/I2MTC43012.2020.9128564

Podaci o odgovornosti

Lučev Vasić, Željka ; Cifrek, Mario ; Gao, Yueming ; Du, Min

engleski

Preliminary Characterization of Capacitive Intrabody Communication Channel under Implantable-Like Conditions

In intrabody communication (IBC) conductive properties of the human body are exploited for establishing communication between devices on, in, or very near the human body. Usually, galvanic coupling is used for establishing communication with implanted devices, and capacitive coupling for communication with the devices on or very close to the skin. It was shown recently that capacitive IBC electrodes can be used for establishing communication with implanted devices as well, and first implantable capacitive IBC channel investigations were performed on human body phantoms, animal tissue, and by numerical simulations. In this paper, we present the first in vivo measurements of in- body to on-body capacitive IBC channel emulated by body-worn electrodes and compare it to an equivalent on-body to on-body IBC link. In-body to on-body channel was realized placing transmitter electrodes under the armpit and taking different body positions, while covering transmitter electrodes with tissue. Measurements of transmission characteristics were performed in the frequency range between 100 kHz and 100 MHz using a network analyzer and a pair of symmetrical balun transformers.

intrabody communication ; capacitive coupling ; implantable device ; in-body to on-body communication channel

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1-5.

2020.

objavljeno

10.1109/I2MTC43012.2020.9128564

Podaci o matičnoj publikaciji

2020 IEEE International Instrumentation and Measurement Technology Conference Proceedings

Rapuano, Sergio ; Van Moer, Wendy ; Vasic, Darko

Piscataway (NJ): Institute of Electrical and Electronics Engineers (IEEE)

Podaci o skupu

2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC 2020)

predavanje

25.05.2020-29.05.2020

Dubrovnik, Hrvatska

Povezanost rada

Elektrotehnika

Poveznice