Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Workplace Sitting Breaks Questionnaire (SITBRQ): an assessment of concurrent validity and test-retest reliability (CROSBI ID 276087)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Pedišić, Željko ; Bennie, Jason A. ; Timperio, Anna F. ; Crawford, David A. ; Dunstan, David W. ; Bauman, Adrian E. ; Salmon, Jo Workplace Sitting Breaks Questionnaire (SITBRQ): an assessment of concurrent validity and test-retest reliability // BMC public health, 14 (2014), 1249, 1

Podaci o odgovornosti

Pedišić, Željko ; Bennie, Jason A. ; Timperio, Anna F. ; Crawford, David A. ; Dunstan, David W. ; Bauman, Adrian E. ; Salmon, Jo

engleski

Workplace Sitting Breaks Questionnaire (SITBRQ): an assessment of concurrent validity and test-retest reliability

Background Breaks in prolonged sitting may have beneficial cardiometabolic and musculoskeletal health outcomes. Desk-based work settings are an important environment to promote and support breaks in sitting time. However, few studies have reported the psychometric properties of self-report measures to assess the frequency and duration of breaks from sitting. This study examined the concurrent validity and test- retest reliability of the Workplace Sitting Breaks Questionnaire (SITBRQ) designed to assess frequency and duration of breaks in sitting within desk-based work settings. Methods To assess the concurrent validity, a sample of 147 desk-based employees completed the SITBRQ and wore an Actigraph GT1M accelerometer for seven consecutive days. To establish test- retest reliability, SITBRQ was administered on two separate occasions 7–14 days apart to a separate sample of 96 desk-based employees. Results A low relative agreement with accelerometry (Spearman’s r = 0.24 [95% CI 0.07 - 0.40]) was determined for self-reported frequency, but not for the duration of sitting breaks (Spearman’s r = 0.05 [95% CI −0.12 - 0.22]). Adequate reliability was determined for both self- reported frequency (Spearman’s r = 0.71 [95% CI 0.59 - 0.79], Cohen’s kappa = 0.74 [95% CI 0.64 - 0.84]) and duration of sitting breaks (Spearman’s r = 0.59 [95% CI 0.45 - 0.71], Cohen’s kappa = 0.61 [95% CI 0.38 - 0.85]). Conclusion SITBRQ may be used for assessment of the frequency of sitting breaks within desk-based work settings with validity and reliability similar to other self-reports in the field of sedentary behaviour research. However, until adequately improved and re-evaluated, it should not be used to collect data about the duration of breaks in sitting time.

cardiometabolic health ; musculoskeletal health ; breaks from sitting

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

14

2014.

1249

1

objavljeno

1471-2458

Povezanost rada

Kineziologija

Indeksiranost