Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Pretreatment for the reclamation of rendering plant secondary effluent with NF/RO: UF flat sheet versus UF hollow fiber membranes (CROSBI ID 274741)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Racar, Marko ; Obajdin, Klaudija ; Dolar, Davor ; Košutić, Krešimir Pretreatment for the reclamation of rendering plant secondary effluent with NF/RO: UF flat sheet versus UF hollow fiber membranes // Clean technologies and environmental policy, 22 (2020), 399-408. doi: 10.1007/s10098-019-01789-8

Podaci o odgovornosti

Racar, Marko ; Obajdin, Klaudija ; Dolar, Davor ; Košutić, Krešimir

engleski

Pretreatment for the reclamation of rendering plant secondary effluent with NF/RO: UF flat sheet versus UF hollow fiber membranes

Rendering plants produce large amounts of wastewater that could be reused at the plant with adequate treatment. Membrane fouling is the main problem during the treatment of this type of wastewater by nanofiltration (NF) and reverse osmosis (RO). In order to reduce membrane fouling, the rendering plant secondary effluent was pretreated with two types of ultrafiltration (UF) membranes: MW as a flat sheet and ZW-1 as a hollow fiber membrane. The fouling on NF/RO flat sheet membranes (NF90, NF270, and XLE) was evaluated with the resistance-in-series model, while the fouling mechanisms were assessed with crossflow models. The UF, NF, and RO permeates were characterized to determine its suitability for reuse in the rendering plant. ZW-1 reduced the flux decline by 67.0% for NF270, 1.6% for NF90, and 38.0% for XLE ; while MW reduced the flux decline by 72.4% for NF270, 50.1% for NF90, and 68.1% for XLE. The pretreatment with MW resulted in higher fouling reduction and a permeate that is appropriate for industrial reuse (washing purposes in the rendering plant). In terms of fouling resistance, NF270 and XLE membranes showed less fouling resistance during the treatment compared to NF90. The highest quality of permeate was obtained with XLE membrane, satisfying the water requirements for steam generation. The predominant fouling mechanisms for NF/RO were partial and complete pore blocking. The best combination for rendering plant secondary effluent reclamation was UF with MW membrane and RO with XLE membrane.

Rendering plant secondary effluent ; Ultrafiltration ; Fouling ; Hollow fiber ; Flat sheet ; Nanofiltration

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

22

2020.

399-408

objavljeno

1618-954X

1618-9558

10.1007/s10098-019-01789-8

Povezanost rada

Interdisciplinarne tehničke znanosti, Kemijsko inženjerstvo

Poveznice
Indeksiranost