Room Classification Based on EMC Conditions in Nuclear Power Plants (CROSBI ID 274360)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Grganić, Hrvoje ; Grgić, Davor ; Šadek, Siniša Room Classification Based on EMC Conditions in Nuclear Power Plants // Energies (Basel), 13 (2020), 2; 359, 18. doi: 10.3390/en13020359

Podaci o odgovornosti

Grganić, Hrvoje ; Grgić, Davor ; Šadek, Siniša

engleski

Room Classification Based on EMC Conditions in Nuclear Power Plants

Electromagnetic compatibility (EMC) in nuclear power plants today mostly relies on the qualification tests of the new equipment and adhering to some good installation practices. Diversity of the electromagnetic environment and different susceptibility of the plant equipment calls for a systematic classification of the EMC zones in a nuclear power plant. The paper proposes a methodology that uses a combination of the qualification tests, in situ and bench immunity tests, site survey measurements, operational experience, and numerical calculations to divide a nuclear power plant into a reasonable number of EMC zones. This would primarily help to have a better overview of the current EMC level in the plant and to unify emission and susceptibility requirements for the new equipment. In this paper, special attention is given to the preparation and performance of the in situ tests, which present the most challenging step of the methodology. In addition, the paper proposes some of the possible applications of the numerical calculations and addresses their challenges and limitations. The novel classification methodology, inspired by the equipment qualification program, is illustrated with examples from Krško Nuclear Power Plant, which recently performed a comprehensive EMC assessment.

electromagnetic compatibility ; electromagnetic immunity ; electromagnetic fields ; in situ tests ; nuclear power plants

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

13 (2)

2020.

359

18

objavljeno

1996-1073

10.3390/en13020359