Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Posttraumatska opskrba u estetskoj zoni primjenom trabekularnoga tantalskoga dentalnoga implantata - prikaz slučaja (CROSBI ID 686429)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Meniga Koncul, Ena ; Morelato, Luka ; Pelivan, Ivica ; Gabrić, Dragana Post-traumatic treatment in the aesthetic zone using an trabecular tantalum dental implant – a case report / Posttraumatska opskrba u estetskoj zoni primjenom trabekularnoga tantalskoga dentalnoga implantata - prikaz slučaja // Acta stomatologica Croatica / Brkić, Hrvoje (ur.). 2019. str. 403-403

Podaci o odgovornosti

Meniga Koncul, Ena ; Morelato, Luka ; Pelivan, Ivica ; Gabrić, Dragana

hrvatski

Posttraumatska opskrba u estetskoj zoni primjenom trabekularnoga tantalskoga dentalnoga implantata - prikaz slučaja

Trabecular tantalum is a unique, highly porous biomaterial made of elemental tantalum with structural, functional and physiological properties similar to bone. It has an open, constructed and interconnected pore structure to support bone growth and vascularization. The material is bioinert, biocompatible and corrosion resistant and has over 20 years of successful clinical application in various orthopaedic indications. The design of the tantalum, as the name implies, resembles bone trabeculae, which further encourages osteoconduction and osseointegration. A case is presented in which, due to a fracture of the upper left central incisor (tooth 21), an extraction was indicated. After mucoperiosteal flap elevation, the tooth was atraumatically extracted using a piezoelectric device and the defect augmented with a combination of a xenogeneic bone graft and PRGF Endoret® technology. The wound was sutured with a non- resorbable suture. During the healing period, patient was provided with a provisional prosthodontics made from the crown of her own tooth. After 10 months, a control panoramic x- ray and a CBCT were taken and surgery was planned. With a minimally invasive technique, without extensive flap elevation, a Zimmer Biomet Trabecular Metal™ implant (4.1x11.5) was placed, soft tissue sutured with a non- resorbable suture and allowed 4 months to osseointegrate. Two days after the healing abutment was placed, an impression was taken using a single-phase technique. A temporary acrylic CAD/CAM crown was made on a PEEK abutment. In addition to the aesthetic and phonetic functions, the purpose of the temporary crown was to design the best possible emergence profile for a future, final crown. After 6 weeks, final impressions were taken and a complete lithium-disilicate ceramic crown was made with an individual CAD/CAM abutment made from zirconium oxide ceramic on a titanium link.

koštana regeneracija ; augmentacija alveolarnog grebena ; koštani nadomjestni materijali

Sažeci skupa: https://ascro.hr/fileadmin/user_upload/2019/Number_2019-4/12_abstracts_-_Dental_Implantology_2019-4.pdf

engleski

Post-traumatic treatment in the aesthetic zone using an trabecular tantalum dental implant – a case report

Trabecular tantalum is a unique, highly porous biomaterial made of elemental tantalum with structural, functional and physiological properties similar to bone. It has an open, constructed and interconnected pore structure to support bone growth and vascularization. The material is bioinert, biocompatible and corrosion resistant and has over 20 years of successful clinical application in various orthopaedic indications. The design of the tantalum, as the name implies, resembles bone trabeculae, which further encourages osteoconduction and osseointegration. A case is presented in which, due to a fracture of the upper left central incisor (tooth 21), an extraction was indicated. After mucoperiosteal flap elevation, the tooth was atraumatically extracted using a piezoelectric device and the defect augmented with a combination of a xenogeneic bone graft and PRGF Endoret® technology. The wound was sutured with a non- resorbable suture. During the healing period, patient was provided with a provisional prosthodontics made from the crown of her own tooth. After 10 months, a control panoramic x- ray and a CBCT were taken and surgery was planned. With a minimally invasive technique, without extensive flap elevation, a Zimmer Biomet Trabecular Metal™ implant (4.1x11.5) was placed, soft tissue sutured with a non- resorbable suture and allowed 4 months to osseointegrate. Two days after the healing abutment was placed, an impression was taken using a single-phase technique. A temporary acrylic CAD/CAM crown was made on a PEEK abutment. In addition to the aesthetic and phonetic functions, the purpose of the temporary crown was to design the best possible emergence profile for a future, final crown. After 6 weeks, final impressions were taken and a complete lithium-disilicate ceramic crown was made with an individual CAD/CAM abutment made from zirconium oxide ceramic on a titanium link.

bone regeneration ; alveolar ridge augmentation ; bone substitutes

Sažeci skupa: https://ascro.hr/fileadmin/user_upload/2019/Number_2019-4/12_abstracts_-_Dental_Implantology_2019-4.pdf

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

403-403.

2019.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Acta stomatologica Croatica

Brkić, Hrvoje

Zagreb: Stomatolški fakultet Sveučilišta u Zagrebu

0001-7019

1846-0410

Podaci o skupu

8th International Congress of the Croatian Society of Dental Implantology of the Croatian Medical Association = 8. Međunarodni kongres Hrvatskoga društva za dentalnu implantologiju Hrvatskoga liječničkog zbora

poster

10.10.2019-12.10.2019

Split, Hrvatska

Povezanost rada

Dentalna medicina

Indeksiranost