Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Improved surface extraction of multi-material components for single-source industrial X-ray computed tomography (CROSBI ID 272645)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Sokac, Mario ; Budak, Igor ; Katic, Marko ; Jakovljevic, Zivana ; Santosi, Zeljko ; Vukelic, Djordje Improved surface extraction of multi-material components for single-source industrial X-ray computed tomography // Measurement, 153 (2019), 107438, 14. doi: 10.1016/j.measurement.2019.107438

Podaci o odgovornosti

Sokac, Mario ; Budak, Igor ; Katic, Marko ; Jakovljevic, Zivana ; Santosi, Zeljko ; Vukelic, Djordje

engleski

Improved surface extraction of multi-material components for single-source industrial X-ray computed tomography

The paper demonstrates a novel methodology for surface extraction of multi-material components (MMCs) on industrial X-ray computed tomography (CT) datasets. The methodology is based on a combination of fuzzy C-means clustering (FCM) and region growing (RG) methods. FCM, used as a pre- processing step, allows proper classification and improvement of different objects boundaries present on industrial X-ray CT datasets. Afterwards, application of RG method enables accurate segmentation of classified and improved X-ray CT datasets. The performance of presented approach has been tested on two CT datasets acquired on an industrial X-ray CT system NIKON XT H 225. It was also compared against two commercial industrial software VGStudio Max v3.1 and GOM Inspect v2018. Obtained results from application of the proposed approach show significant improvement in surface extraction of MMCs in CT datasets, especially in cases of low-density materials such as polymers. Verification has been conducted by obtaining reference measurements using contact coordinate measurement machine (CMM) Contura G2 by CARL ZEISS.

X-ray computed tomography ; multi-material component (MMC) ; edge detection ; dimensional CT measurement ; metrology

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

153

2019.

107438

14

objavljeno

0263-2241

1873-412X

10.1016/j.measurement.2019.107438

Povezanost rada

Strojarstvo

Poveznice
Indeksiranost