Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Mechanical properties and water sorption of two experimental glass ionomer cements with hydroxyapatite or calcium fluorapatite formulation (CROSBI ID 271323)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bilge Kutuk, Zeynep ; Koc Vural, Uzay ; Yalcin Cakir, Filiz ; Miletić, Ivana ; Gurgan Sevil Mechanical properties and water sorption of two experimental glass ionomer cements with hydroxyapatite or calcium fluorapatite formulation // Dental materials journal, 38 (2019), 3; 471-479

Podaci o odgovornosti

Bilge Kutuk, Zeynep ; Koc Vural, Uzay ; Yalcin Cakir, Filiz ; Miletić, Ivana ; Gurgan Sevil

engleski

Mechanical properties and water sorption of two experimental glass ionomer cements with hydroxyapatite or calcium fluorapatite formulation

In this study the mechanical behavior and water sorption (Ws) of experimental glass-ionomer-cements (GICs) with hydroxyapatite (HA) or calcium fluorapatite (CFA) prototype formulations were examined. Specimens from two experimental and one commercially available GIC were prepared in three protocols ; (1) according to the manufacturer’s instructions, (2) with coating and (3) with heat application. The specimens were stored in distilled water or artificial saliva at 37°C for 7- and 30-days. Flexural strength (FS), Vickers hardness (VHN) and Ws of GICs were evaluated. Experimental GICs showed higher FS values than commercial GIC (p<0.001). Higher FS and VHN values were observed when GICs were prepared according to manufacturer’s recommendation. FS was affected only by GIC- type (η2=0.027), whereas VHN was affected by GIC-type (η2=0.331), treatment-protocols (η2=0.067), storage-medium (η2=0.100) and increased storage-duration (η2=0.317). The tested parameters did not significantly influence the Ws of all tested GICs (p>0.05). The GICs with HA or CFA formulations might represent a promising approach due to their FS, VHN and Ws characteristics.

Glass ionomer cement ; Hydroxyapatite ; Fluorapatite ; Calcium fluorapatite ; Mechanical properties

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

38 (3)

2019.

471-479

objavljeno

0287-4547

1881-1361

Povezanost rada

Dentalna medicina

Indeksiranost