Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

A simplified fetal biophysical profile (CROSBI ID 270769)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Petrović, O. ; Škunca, E. ; Matejčić, N. A simplified fetal biophysical profile // International journal of gynaecology and obstetrics, 61 (1998), 1; 9-14. doi: 10.1016/s0020-7292(98)00009-5

Podaci o odgovornosti

Petrović, O. ; Škunca, E. ; Matejčić, N.

engleski

A simplified fetal biophysical profile

Objective: To modify the classic fetal biophysical profile (FBP) with the aim of obtaining rapid and accurate information about actual fetal condition in non‐compromised fetuses with a subsequent favorable outcome and to be suitable for a number of outclinic patients. Methods: Four‐hundred and ninety‐four fetuses from singleton pregnancies in two randomized groups were monitored by the modified FBP (mFBP) and 168 of them after the external vibratory acoustic stimulation (VAS/mFBP). The mFBP was characterized by two main characteristics: non‐stress test was excluded and the testing was finished at the moment when all of the three fetal biophysical activities became normal. The external VAS was applied only in cases with no evidence of fetal activity at the start of the FBP. Results: Of the examined fetuses, 326 fetuses in the control group were monitored by the mFBP and there were 316 (96.9%) favorable outcomes and 10 (3.1%) adverse perinatal outcomes. The sensitivity, specificity and positive and negative predictive values of the mFBP score in predicting adverse perinatal outcome were 60, 99, 66.7 and 98.7%, respectively. In the study group of 168 fetuses there were 165 (98.2%) favorable outcomes and three (1.8%) adverse perinatal outcomes. The sensitivity, specificity and positive and negative predictive values of the VAS/mFBP were 66.7, 100, 100 and 99.4%, respectively. The efficiency of the VAS/mFBP in predicting perinatal mortality alone was even higher. After the external VAS and the first 5 min of the modified testing approximately two‐fifths (41.8%) of healthy fetuses with a subsequent good outcome exhibited normal in all of the three biophysical activities and approximately two‐thirds (65.5%) of them after 10 min. In the VAS/mFBP group of healthy fetuses, during the same time periods, normal breathing movements were observed in 72% and 87% of fetuses, respectively. Conclusions: According to our results the mFBP and particularly the VAS/mFBP antenatal protocol as a new and rational variant of the FBP could improve fetal assessment allowing in cases of non‐compromised fetuses rapid and accurate information about actual fetal well‐being. Because of its high accuracy and a reduced testing time the antepartal method with observation of fetal breathing movements after VAS is becoming acceptable as a screening of fetal well‐being evaluation in outclinic conditions.

modified fetal biophysical profile ; breathing movements ; vibratory acoustic stimulation ; fetal assessment ; perinatal outcome ; outclinic patients

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

61 (1)

1998.

9-14

objavljeno

0020-7292

10.1016/s0020-7292(98)00009-5

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost