Učinkovitost VPCI čistača na bazi vode za odmašćivanje površine i utjecaj na prionjivost premaza

Before application of coatings, various methods of surface preparation are used to remove contaminants and achieve optimum surface roughness. The classic methods of surface preparation such as sandblasting have been proven to be effective in the removal of corrosion products and to achieve the desired degree of roughness, but such a method of surface preparation requires a degreasing process. For this purpose, most commonly different types of surface cleaners are used. Thinners are often used, but for environmental reasons attempt to be replaced with a water based cleaner with the addition of corrosion inhibitors. The great advantage of the new method is that, at the same time, temporary protection against corrosion is achieved. Three water-based cleaners with a volatile corrosion inhibitor were studied, and their efficiency was compared with steel samples prepared by classical methods of sandblasting and degreasing by thinner. Acrylic coatings (with and without volatile inhibitors) were applied to the prepared surface. The tests were carried out in the salt spray and humidity chamber, after which the coating adhesion was tested by the cross-cut method. Electrochemical impedance spectroscopy showed resistance of coating in 3.5% NaCl solution. Studied acrylic coatings containing volatile corrosion inhibitors showed better corrosion resistance in the humidity and salt spray chamber.

prionjivost, VPCI inhibitor

nije evidentirano

engleski

EFFICIENCY OF VpCI WATER-BASED CLEANERS FOR SURFACE PREPARATION AND IMPACT ON COATING ADHESION

nije evidentirano

adhesion, VPCI inhibitor

nije evidentirano

Podaci o prilogu

247-260.

2019.

objavljeno

Podaci o matičnoj publikaciji

Markučič , Damir

Zagreb: Hrvatsko društvo za materijale i tribologiju (HDMT)

2584-4334

Podaci o skupu

2nd International Conference on Materials (MTECH 2019)

predavanje

09.10.2019-12.10.2019

Poreč, Hrvatska

Povezanost rada

Kemijsko inženjerstvo, Strojarstvo