Comparison of digitizers for high precision sampling power meters (CROSBI ID 269202)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Konjevod Jure ; Malarić Roman ; Jurčević Marko ; Mostarac Petar ; Dadić Martin Comparison of digitizers for high precision sampling power meters // IEEE transactions on instrumentation and measurement, 69 (2019), 6; 3719-3728. doi: 10.1109/TIM.2019.2941260

Podaci o odgovornosti

Konjevod Jure ; Malarić Roman ; Jurčević Marko ; Mostarac Petar ; Dadić Martin

engleski

Comparison of digitizers for high precision sampling power meters

This paper compares different measuring equipment, especially sampling devices used in sampling power measuring standards. Several most frequently used digitizers are compared: HP3458A, NI 5922 and NI 4461. To calculate electric power following parameters are relevant: voltage amplitude, current amplitude and phase difference between voltage and current. These parameters are obtained by application of three different correction algorithms: IpDFT, 4PSF and PSFE algorithm. The results are presented with several comparisons to get insight into performances of the digitizers which are suitable for precise power measurement as well as for calibration of equipment.

Digital sampling wattmeter , sampling measurement devices , electric power measurement , correction algorithm