Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Comparison of Surgisis, Vypro II and TiMesh in contaminated and clean field (CROSBI ID 268602)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Filipović-Čugura, Jakša ; Misir, Zvonimir ; Hrabač, Pero ; Orešić, Tomislav ; Vidović, Dinko ; Misir, Branimir ; Filipović, Nika ; Kirac, Iva ; Mijić, August Comparison of Surgisis, Vypro II and TiMesh in contaminated and clean field // Hernia, 24 (2019), 3; 551-558. doi: 10.1007/s10029-019-01949-1

Podaci o odgovornosti

Filipović-Čugura, Jakša ; Misir, Zvonimir ; Hrabač, Pero ; Orešić, Tomislav ; Vidović, Dinko ; Misir, Branimir ; Filipović, Nika ; Kirac, Iva ; Mijić, August

engleski

Comparison of Surgisis, Vypro II and TiMesh in contaminated and clean field

The study aimed to evaluate the histologic properties and infection resistance of three different mesh materials in a rat model. Each mesh, in both infectious (n = 96) and non- infectious groups (n = 270), was positioned both in sublay (preperitoneally) and onlay (subcutaneously) locations. Properties of the biological (Surgisis ; Cook Surgical), composite, partially resorbing (Vypro II mesh ; Ethicon) and non-resorbing (TiMesh ; GFE Medizintechnik GmbH) mesh were evaluated and compared. Animals were killed at 7, 21 and 90 days after implantation. The following parameters were evaluated to assess the host response to the mesh material: inflammation, vascularization, fibrosis, collagen formation, Ki67, and a foreign body reaction by granuloma formation (FBG). Surgisis mesh produced more pronounced inflammation and cell proliferation, and less intense granuloma formation, as well as fibrosis, compared to the other two groups. When the infected materials were examined, we found signs of local infection to be more often present in Surgisis group of animals. CONCLUSIONS: In the presence of bacterial contamination, no benefits were observed in the use of the Surgisis prosthesis over the use of TiMesh and Vypro II.

hernia ; infection ; rat model ; surgisis ; timesh ; Vypro II

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

24 (3)

2019.

551-558

objavljeno

1265-4906

1248-9204

10.1007/s10029-019-01949-1

Povezanost rada

Kliničke medicinske znanosti

Poveznice
Indeksiranost