Dose mapping of the panoramic 60Co gamma irradiation facility at the Ruđer Bošković Institute – Geant4 simulation and measurements (CROSBI ID 268461)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Majer, Marija ; Roguljić, Matej ; Knežević, Željka ; Starodumov, Andrey ; Ferenček, Dinko ; Brigljević, Vuko ; Mihaljević, Branka
engleski
Dose mapping of the panoramic 60Co gamma irradiation facility at the Ruđer Bošković Institute – Geant4 simulation and measurements
The paper presents the dose mapping of the panoramic 60Co gamma irradiation facility at the Ruđer Bošković Institute in Croatia. Both experimental (using ionisation chamber) and simulation (using the Geant4 Monte Carlo code) studies have been performed and compared. Measured and simulation dose rates are found to be in very good agreement and can be used for the absorbed dose determination in the irradiation chamber in everyday work. In order to get a complete description of the dose distribution in the facility, the transit dose, which has to be taken into consideration at low doses, was also experimentally determined.
60Co gamma irradiation facility ; Dosimetry ; Geant4 ; Dose mapping ; Transit dose
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
154
2019.
108824
7
objavljeno
0969-8043
10.1016/j.apradiso.2019.108824