Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Prediction of the Seismic Response of Multi- Storey Multi-Bay Masonry Infilled Frames Using Artificial Neural Networks and a Bilinear Approximation (CROSBI ID 266333)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kalman Šipoš, Tanja ; Strukar, Kristina Prediction of the Seismic Response of Multi- Storey Multi-Bay Masonry Infilled Frames Using Artificial Neural Networks and a Bilinear Approximation // Buildings, 9 (2019), 5; 121, 21. doi: 10.3390/buildings9050121

Podaci o odgovornosti

Kalman Šipoš, Tanja ; Strukar, Kristina

engleski

Prediction of the Seismic Response of Multi- Storey Multi-Bay Masonry Infilled Frames Using Artificial Neural Networks and a Bilinear Approximation

In order to test the reliability of neural networks for the prediction of the behaviour of multi-storey multi-bay infilled frames, neural network processing was done on an experimental database of one-storey one-bay reinforced- concrete (RC) frames with masonry infills. From the obtained results it is demonstrated that they are acceptable for the prediction of base shear (BS) and inter-storey drift ratios (IDR) in characteristic points of the primary curve of infilled frame behaviour under seismic loads. The results obtained on one-storey one-bay infilled frames was extended to multi-bay infilled frames by evaluating and comparing numerical finite element modelling(FEM) modelling and neural network results with suggested approximating equations for the definition of bilinear capacity by defined BS and IDRs. The main goal of this paper is to offer an interpretation of the behaviour of multi-storey multi-bay masonry infilled frames according to a bilinear capacity curve, and to present the infilled frame’s response according to the contributions of frame and infill. The presented methodology is validated by experimental results from multi-storey multi-bay masonry infilled frames.

masonry ; infilled frames ; capacity curve ; bilinear approximation ; neural networks ; database

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

9 (5)

2019.

121

21

objavljeno

2075-5309

10.3390/buildings9050121

Trošak objave rada u otvorenom pristupu

APC

Povezanost rada

Građevinarstvo, Temeljne tehničke znanosti

Poveznice
Indeksiranost